SAM9XE512 Atmel Corporation, SAM9XE512 Datasheet - Page 469

no-image

SAM9XE512

Manufacturer Part Number
SAM9XE512
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9XE512

Flash (kbytes)
512 Kbytes
Pin Count
217
Max. Operating Frequency
180 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
96
Ext Interrupts
96
Usb Transceiver
3
Usb Speed
Full Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
2
Uart
6
Ssc
1
Ethernet
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
Yes
Adc Channels
4
Adc Resolution (bits)
10
Adc Speed (ksps)
312
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.65 to 1.95
Fpu
No
Mpu / Mmu
No / Yes
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
No
33.9.4.2
33.9.4.3
33.9.4.4
33.9.4.5
33.9.5
33.9.5.1
469
AT91SAM9XE128/256/512 Preliminary
Data Transfer
Write Sequence
Clock Synchronization Sequence
General Call
PDC
Read Operation
Note that a STOP or a repeated START always follows a NACK.
See
In the case of a Write sequence (SVREAD is low), the RXRDY (Receive Holding Register
Ready) flag is set as soon as a character has been received in the TWI_RHR (TWI Receive
Holding Register). RXRDY is reset when reading the TWI_RHR.
TWI continues receiving data until a STOP condition or a REPEATED_START + an address dif-
ferent from SADR is detected. Note that at the end of the write sequence TXCOMP flag is set
and SVACC reset.
See
In the case where TWI_THR or TWI_RHR is not written/read in time, TWI performs a clock
synchronization.
Clock stretching information is given by the SCLWS (Clock Wait state) bit.
See
In the case where a GENERAL CALL is performed, GACC (General Call ACCess) flag is set.
After GACC is set, it is up to the programmer to interpret the meaning of the GENERAL CALL
and to decode the new address programming sequence.
See
As it is impossible to know the exact number of data to receive/send, the use of PDC is NOT rec-
ommended in SLAVE mode.
The read mode is defined as a data requirement from the master.
After a START or a REPEATED START condition is detected, the decoding of the address
starts. If the slave address (SADR) is decoded, SVACC is set and SVREAD indicates the direc-
tion of the transfer.
Until a STOP or REPEATED START condition is detected, TWI continues sending data loaded
in the TWI_THR register.
If a STOP condition or a REPEATED START + an address different from SADR is detected,
SVACC is reset.
Figure 33-25 on page 470
Figure 33-25 on page
Figure 33-26 on page
Figure 33-28 on page 472
Figure 33-27 on page
describes the write operation.
470.
470.
471.
and
Figure 33-29 on page
473.
6254C–ATARM–22-Jan-10

Related parts for SAM9XE512