is43dr16128 Integrated Silicon Solution, Inc., is43dr16128 Datasheet - Page 5

no-image

is43dr16128

Manufacturer Part Number
is43dr16128
Description
2gb X16 Ddr2 Sdram
Manufacturer
Integrated Silicon Solution, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
is43dr16128-3DBLI
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Company:
Part Number:
is43dr16128A-3DBLI
Quantity:
148
Part Number:
is43dr16128B-25EBLI
Manufacturer:
BROADCOM
Quantity:
6 700
Part Number:
is43dr16128B-3DBLI
Manufacturer:
ISSI
Quantity:
20 000
Company:
Part Number:
is43dr16128C-25DBLI
Quantity:
12 000
IS43/46DR16128 
Mode Register (MR) Diagram 
Notes: 
1.
DDR2 Extended Mode Register 1 (EMR[1]) Setting  
The  extended  mode  register  1  stores  the  data  for  enabling  or  disabling  the  DLL,  output  driver  strength,  ODT  value  selection  and 
additive  latency.  The  default  value  of  the  extended  mode  register  is  not  defined,  therefore  the  extended  mode  register  must  be 
written after power‐up for proper operation. Extended mode register 1 is written by asserting LOW on CS#, RAS#, CAS#, WE#, BA1, 
and BA2, and HIGH on BA0, and controlling pins A0 – A13. The DDR2 SDRAM should be in all bank precharge with CKE already HIGH 
prior to writing into the extended mode register. The mode register set command cycle time (tMRD) must be satisfied to complete 
the  write  operation  to  the  extended  mode  register.  Mode  register  contents  can  be  changed  using  the  same  command  and  clock 
cycle requirements during normal operation as long as all banks are in the precharge state. A0 is used for DLL enable or disable. A1 is 
used for enabling reduced strength data‐output driver. A3 ‐ A5 determines the additive latency, A2 and A6 are used for ODT value 
selection, A7 ‐ A9 are used for OCD control, A10 is used for DQS# disable and A11 is used for RDQS enable. 
 
Integrated Silicon Solution, Inc. – www.issi.com –
Rev. 00B, 3/28/2011
WR(write recovery for autoprecharge) min is determined by tCK max and WR max is determined by tCK min. WR in clock cycles is calculated by dividing tWR (in 
ns) by tCK (in ns) and rounding up a non‐integer value to the next integer (WR[cycles] = tWR(ns)/tCK(ns)). The mode register must be programmed to this value. 
This is also used with tRP to determine tDAL. 
Address 
Field
BA2
BA1
BA0
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
Register
Latency
Length
Mode 
Burst 
PD1
WR
DLL
CAS 
TM
BT
0
0
0
0
A12
A11
A8
A6
A3
A2
0
1
0
0
0
0
1
1
1
1
0
1
0
0
0
0
1
1
1
1
0
1
0
0
A10
Active power down exit time
A5
A1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
1
1
Slow exit(use tXARDS)
Fast exit (use tXARD)
Burst Type
Sequential
Interleave
DLL Reset
Yes
A9
No
A4
A0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
WR(cycles)
BL
4
8
Reserved
2
3
4
5
6
7
8
CAS Latency
Reserved
Reserved
Reserved
(1)
3
4
5
6
7
A7
0
1
Reserved
Normal
Mode
 
5

Related parts for is43dr16128