M58LT128HSB8ZA6 NUMONYX [Numonyx B.V], M58LT128HSB8ZA6 Datasheet - Page 19

no-image

M58LT128HSB8ZA6

Manufacturer Part Number
M58LT128HSB8ZA6
Description
Manufacturer
NUMONYX [Numonyx B.V]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M58LT128HSB8ZA6
Manufacturer:
ST
Quantity:
10 720
Part Number:
M58LT128HSB8ZA6
Manufacturer:
ST
0
Part Number:
M58LT128HSB8ZA6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M58LT128HSB8ZA6E
Manufacturer:
ST
Quantity:
20 000
Part Number:
M58LT128HSB8ZA6F
Manufacturer:
Numonyx/ST Micro
Quantity:
135
Part Number:
M58LT128HSB8ZA6F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
M58LT128HST, M58LT128HSB
4.3
4.4
Read Electronic Signature command
The Read Electronic Signature command is used to read the manufacturer and device
codes, the protection status of the addressed bank, the Protection Register, and the
Configuration Register.
One Bus Write cycle is required to issue the Read Electronic Signature command. Once a
bank is in Read Electronic Signature mode, subsequent Read operations in the same bank
output the manufacturer code, the device code, the protection status of the addressed bank,
the Protection Register, or the Configuration Register (see
The Read Electronic Signature command can be issued at any time, even during Program
or Erase operations, except during Protection Register Program operations. Dual operations
between the parameter bank and the electronic signature location are not allowed (see
Table 15: Dual operation limitations
If a Read Electronic Signature command is issued to a bank that is executing a Program or
Erase operation the bank go into Read Electronic Signature mode. Subsequent Bus Read
cycles output the Electronic Signature data and the Program/Erase Controller continues to
program or erase in the background.
The Read Electronic Signature command only changes the Read mode of the addressed
bank. The Read modes of other banks are not affected. Only Asynchronous Read and
Single Synchronous Read operations should be used to read the Electronic Signature. A
Read Array command is required to return the bank to Read Array mode.
Read CFI Query command
The Read CFI Query command is used to read data from the Common Flash Interface
(CFI).
One Bus Write cycle is required to issue the Read CFI Query command. Once a bank is in
Read CFI Query mode, subsequent Bus Read operations in the same bank read from the
Common Flash Interface. The Read CFI Query command can be issued at any time, even
during Program or Erase operations.
If a Read CFI Query command is issued to a bank that is executing a Program or Erase
operation the bank goes into Read CFI Query mode. Subsequent Bus Read cycles output
the CFI data and the Program/Erase controller continues to Program or Erase in the
background.
The Read CFI Query command only changes the Read mode of the addressed bank. The
Read modes of other banks are not affected. Only Asynchronous Read and Single
Synchronous Read operations should be used to read from the CFI. A Read Array
command is required to return the bank to Read Array mode. Dual operations between the
Parameter Bank and the CFI memory space are not allowed (see
limitations
See
for details on the information contained in the Common Flash Interface memory area.
Appendix B: Common Flash
for details).
Interface, Tables 31, 32, 33, 34, 35, 36, 37, 38,
for details).
Table
8).
Table 15: Dual operation
Command interface
39
and
19/110
40

Related parts for M58LT128HSB8ZA6