MAX9263GCB/V+T Maxim Integrated, MAX9263GCB/V+T Datasheet - Page 43

no-image

MAX9263GCB/V+T

Manufacturer Part Number
MAX9263GCB/V+T
Description
Serializers & Deserializers - Serdes GMSL Serializer w/HDCP Interface
Manufacturer
Maxim Integrated
Datasheet
Figure 30. Serializer State Diagram, CDS = Low (LCD Application)
After power-up or when PWDN transitions from low to
high, the remote device (deserializer) starts up and tries
to lock to an incoming serial signal with sufficient power.
The host side (serializer) is in standby mode and does
not try to establish a link. Use the FC and program the
serializer to set SEREN = 1 (and apply a stable clock
signal) to establish a video link or CLINKEN = 1 to estab-
lish the configuration link. In this case, the deserializer
ignores the short wake-up signal sent from the serializer.
After power-up or when PWDN transitions from low to
high, the remote device (deserializer) starts up in sleep
mode. The high-speed link establishes automatically
after the serializer powers up with a stable clock signal
and sends a wake-up signal to the deserializer. Use this
AUTOS PIN
SETTING
HIGH
LOW
PWDN = LOW OR
ALL STATES
POWER-OFF
POWER-UP VALUE
Case 3: Remote Side Autostart Mode
SEREN BIT
Case 4: Remote Side in Sleep Mode
1
0
PWDN = HIGH
AUTOS = LOW
OR POWER-OFF
POWER-DOWN
POWER-ON,
PCLKIN RUNNING
PWDN = HIGH,
LINK LOCKING
AUTOS = LOW
POWER-ON
SEREN = 1,
HDCP Gigabit Multimedia Serial
VIDEO
VIDEO LINK
UNLOCKED
VIDEO LINK
SEREN = 0, OR
LOCKED
POWER-ON
Link Serializer/Deserializer
NO PCLKIN
IDLE
mode in applications where the deserializer powers up
before the serializer.
For image-sensing applications, connect the FC to the
deserializer and set CDS = high for both the serializer
and deserializer. The deserializer powers up normally
(SLEEP = 0) and continuously tries to lock to a valid
serial input. Table 14 summarizes both startup cases,
based on the state of the serializer’s AUTOS pin.
After power-up, or when PWDN transitions from low to
high, the serializer locks to a stable input clock and
sends the high-speed data to the deserializer. The dese-
rializer locks to the serial data and outputs the video data
and clock.
CLINKEN = 0 OR
CLINKEN = 1
SEREN = 1
SEREN = 0,
NO PCLKIN
VIDEO LINK
OPERATING
CLINKEN = 0 OR
LINK STARTING
SEREN = 1
CONFIG
PRBSEN = 0
PRBSEN = 1
Image-Sensing Applications
CONFIG LINK
CONFIG LINK
UNLOCKED
LOCKED
VIDEO LINK
PRBS TEST
Case 1: Autostart Mode
CONFIG LINK
OPERATING
REGISTERS
PROGRAM
43