PC48F4400P0TB0EE NUMONYX, PC48F4400P0TB0EE Datasheet - Page 61

no-image

PC48F4400P0TB0EE

Manufacturer Part Number
PC48F4400P0TB0EE
Description
IC FLASH 256MBIT 64EZBGA
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of PC48F4400P0TB0EE

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
512M (32Mx16)
Speed
95ns
Interface
Parallel
Voltage - Supply
2.3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
64-EZBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PC48F4400P0TB0EE
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
PC48F4400P0TB0EE
Manufacturer:
MICRON
Quantity:
20 000
Part Number:
PC48F4400P0TB0EE
0
P33-65nm
Appendix A Supplemental Reference Information
A.1
A.1.1
Table 28: Summary of Query Structure Output as a Function of Device and Mode
Datasheet
61
Common Flash Interface
The Common Flash Interface (CFI) is part of an overall specification for multiple
command-set and control-interface descriptions. This appendix describes the database
structure containing the data returned by a read operation after issuing the Read CFI
command (see
software can parse this database structure to obtain information about the flash device,
such as block size, density, bus width, and electrical specifications. The system
software will then know which command set(s) to use to properly perform flash writes,
block erases, reads and otherwise control the flash device.
Query Structure Output
The Query database allows system software to obtain information for controlling the
flash device. This section describes the device’s CFI-compliant interface that allows
access to Query data.
Query data are presented on the lowest-order data outputs (DQ
offset value is the address relative to the maximum bus width supported by the device.
On this family of devices, the Query table device starting address is a 10h, which is a
word address for x16 devices.
For a word-wide (x16) device, the first two Query-structure bytes, ASCII “Q” and “R,”
appear on the low byte at word addresses 10h and 11h. This CFI-compliant device
outputs 00h data on upper bytes. The device outputs ASCII “Q” in the low byte (DQ
and 00h in the high byte (DQ
At Query addresses containing two or more bytes of information, the least significant
data byte is presented at the lower address, and the most significant data byte is
presented at the higher address.
In all of the following tables, addresses and data are represented in hexadecimal
notation, so the “h” suffix has been dropped. In addition, since the upper byte of word-
wide devices is always “00h,” the leading “00” has been dropped from the table
notation and only the lower byte value is shown. Any x16 device outputs have 00h on
the upper byte in this mode.
Device Addresses
Section 6.2, “Device Command Bus Cycles” on page
Device
15-8
).
00010:
00011:
00012:
Offset
Hex
7-0
) only. The numerical
Order Number:320003-09
18). System
Code
Hex
51
52
59
Value
ASCII
"Q"
"R"
"Y"
Mar 2010
7-0
)