TMP86FH46ANG(Z) Toshiba, TMP86FH46ANG(Z) Datasheet - Page 88

IC MCU 8BIT FLASH 16KB 42-SDIP

TMP86FH46ANG(Z)

Manufacturer Part Number
TMP86FH46ANG(Z)
Description
IC MCU 8BIT FLASH 16KB 42-SDIP
Manufacturer
Toshiba
Series
TLCS-870/Cr
Datasheet

Specifications of TMP86FH46ANG(Z)

Core Processor
870/C
Core Size
8-Bit
Speed
16MHz
Connectivity
SIO, UART/USART
Peripherals
LED, PWM, WDT
Number Of I /o
33
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
42-SDIP (0.600", 15.24mm)
Processor Series
TLCS-870
Core
870/C
Data Bus Width
8 bit
Data Ram Size
512 B
Interface Type
SIO, UART
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
33
Number Of Timers
3
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Development Tools By Supplier
BMSKTOPAS86FH47(AND), BM1040R0A, BMP86A100010A, BMP86A100010B, BMP86A200010B, BMP86A200020A, BMP86A300010A, BMP86A300020A, BMP86A300030A, SW89CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
For Use With
BM1401W0A-G - FLASH WRITER ON-BOARD PROGRAMTMP86C909XB - EMULATION CHIP FOR TMP86F SDIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
TMP86FH46ANGZ
8.3 Function
TC1 pin Input
Up-counter
TC1DRA
INTTC1
interrput request
8.3.3 Event Counter Mode
rising or falling edge of the input pulse is selected as the count up edge in TC1CR<TC1S>.
and the up-counter is cleared. After being cleared, the up-counter restarts counting at each edge of the input
pulse to the TC1 pin. Since a match between the up-counter and the value set to TC1DRA is detected at the
edge opposite to the selected edge, an INTTC1 interrupt request is generated after a match of the value at the
edge opposite to the selected edge.
Use the auto-capture function in the operative condition of TC1. A captured value may not be fixed if it's read
after the execution of the timer stop or auto-capture disable. Read the capture value in a capture enabled condi-
tion. Since the up-counter value is captured into TC1DRB by the source clock of up-counter after setting
TC1CR<ACAP1> to "1". Therefore, to read the captured value, wait at least one cycle of the internal source
clock before reading TC1DRB for the first time.
In the event counter mode, the up-counter counts up at the edge of the input pulse to the TC1 pin. Either the
When a match between the up-counter and the TC1DRA value is detected, an INTTC1 interrupt is generated
Two or more machine cycles are required for the low-or high-level pulse input to the TC1 pin.
Setting TC1CR<ACAP1> to “1” captures the up-counter value into TC1DRB with the auto capture function.
?
Table 8-2 Input Pulse Width to TC1 Pin
Timer start
High-going
Low-going
0
n
Figure 8-4 Event Counter Mode Timing Chart
1
NORMAL1/2, IDLE1/2 Mode
2
2
2
3
3
Page 74
/fc
/fc
Minimum Pulse Width [s]
Match detect
n − 1
SLOW1/2, SLEEP1/2 Mode
n
0
Counter clear
2
2
3
3
/fs
/fs
1
2
TMP86FH46ANG
(TC1S = 10)
At the
rising edge

Related parts for TMP86FH46ANG(Z)