HD64F3672FPIV Renesas Electronics America, HD64F3672FPIV Datasheet - Page 223

MCU 3/5V 16K I-TEMP PB-FREE 64-L

HD64F3672FPIV

Manufacturer Part Number
HD64F3672FPIV
Description
MCU 3/5V 16K I-TEMP PB-FREE 64-L
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3672FPIV

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
PWM, WDT
Number Of I /o
26
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-LQFP
For Use With
R0K436079S000BE - KIT DEV FOR H8/36079 W/COMPILER
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Yes
No
No
Figure 13.17 Sample Multiprocessor Serial Reception Flowchart (1)
Read OER and FER flags in SSR
Read OER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Set MPIE bit in SCR3 to 1
Clear RE bit in SCR3 to 0
Read RDRF flag in SSR
Read RDRF flag in SSR
All data received?
This station’s ID?
Start reception
FER+OER = 1
FER+OER = 1
RDRF = 1
RDRF = 1
<End>
Yes
Yes
Yes
No
No
No
[A]
Yes
No
Yes
[3]
[1]
[2]
Error processing
Section 13 Serial Communication Interface 3 (SCI3)
(Continued on
[4]
next page)
[5]
[1]
[2]
[3]
[4]
[5]
Set the MPIE bit in SCR3 to 1.
Read OER and FER in SSR to check for
errors. Receive error processing is performed
in cases where a receive error occurs.
Read SSR and check that the RDRF flag is
set to 1, then read the receive data in RDR
and compare it with this station’s ID.
If the data is not this station’s ID, set the MPIE
bit to 1 again.
When data is read from RDR, the RDRF flag
is automatically cleared to 0.
Read SSR and check that the RDRF flag is
set to 1, then read the data in RDR.
If a receive error occurs, read the OER and
FER flags in SSR to identify the error. After
performing the appropriate error processing,
ensure that the OER and FER flags are all
cleared to 0.
Reception cannot be resumed if either of
these flags is set to 1.
In the case of a framing error, a break can be
detected by reading the RxD pin value.
Rev.4.00 Nov. 02, 2005 Page 197 of 304
REJ09B0143-0400

Related parts for HD64F3672FPIV