R4F24268NVRFQV Renesas Electronics America, R4F24268NVRFQV Datasheet - Page 1170

MCU 256KB FLASH 48K 144-LQFP

R4F24268NVRFQV

Manufacturer Part Number
R4F24268NVRFQV
Description
MCU 256KB FLASH 48K 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2400r
Datasheet

Specifications of R4F24268NVRFQV

Core Processor
H8S/2600
Core Size
16/32-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SSU, UART/USART
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
48K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R4F24268NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
R4F24268NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 22 Clock Pulse Generator
22.3
The system-clock PLL circuit and divider have the function of multiplying the frequency of the
clock from the oscillator by a factor of 1, 2, or dividing by 2. The system clock frequency is set
with the STC1 and STC0 bits in PLLCR. The phase of the rising edge of the internal clock is
controlled so as to match that of the rising edge of the EXTAL pin.
When the frequency is changed with the system-clock PLL circuit and divider, operation varies
according to the setting of the STCS bit in SCKCR.
When STCS = 0, the setting of the changed frequency becomes valid after a transition to software
standby mode. The transition time count is performed in accordance with the setting of bits STS3
to STS0 in SBYCR. For details on SBYCR, see section 23.1.1, Standby Control Register
(SBYCR).
1. The initial PLL circuit multiplication factor is 1.
2. A value is set in bits STS3 to STS0 to give the specified transition time.
3. The target value is set in bits STC1 and STC0, and a transition is made to software standby
4. The clock pulse generator stops and the value set in STC1 and STC0 becomes valid.
5. Software standby mode is cleared, and a transition time is secured in accordance with the
6. After the set transition time has elapsed, this LSI resumes operation using the target
When STCS = 1, a change to the frequency setting becomes effective a maximum of four cycles
after the setting is changed. If the clock frequency is changed during access to an external address
space, correct operation cannot be guaranteed. Therefore, be sure to store instructions that change
the STC1 and STC0 bits and other instructions to be executed within a maximum of four cycles
after the change to the frequency setting in on-chip ROM or on-chip RAM, so that instructions do
not access an external address space before the frequency clock is switched over.
Page 1140 of 1372
mode.
setting in STS3 to STS0.
multiplication factor.
System-Clock PLL Circuit and Divider
H8S/2426, H8S/2426R, H8S/2424 Group
REJ09B0466-0350 Rev. 3.50
Jul 09, 2010

Related parts for R4F24268NVRFQV