SAK-XC864L-1FRI 5V AA Infineon Technologies, SAK-XC864L-1FRI 5V AA Datasheet - Page 105

no-image

SAK-XC864L-1FRI 5V AA

Manufacturer Part Number
SAK-XC864L-1FRI 5V AA
Description
IC MCU 8BIT 4KB FLASH 20TSSOP
Manufacturer
Infineon Technologies
Series
XC8xxr
Datasheet

Specifications of SAK-XC864L-1FRI 5V AA

Core Processor
XC800
Core Size
8-Bit
Speed
86MHz
Connectivity
LIN, SSI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
9
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
20-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
4.2.4
Table 36
Parameter
Active Mode
Idle Mode
Active Mode with slow-down
enabled
Idle Mode with slow-down
enabled
1)
2)
3)
4)
5)
6)
Table 37
Parameter
Power-Down Mode
1)
2)
3)
4)
5)
Data Sheet
V
V
DDP
DDP
The typical
The maximum
I
on-chip oscillator of 10 MHz and NDIV in PLL_CON to 0010
I
enabled and running at 26.7 MHz, RESET =
I
running at 833 KHz by setting CLKREL in CMCON to 0101
I
clock to all peripherals enabled and running at 833 KHz by setting CLKREL in CMCON to 0101
RESET =
The typical
The maximum
I
I
are programmed to be input with either internal pull devices enabled or driven externally to ensure no floating
inputs.
Not subject to production test, verified by design/characterization.
DDP
DDP
DDP
DDP
PDP
PDP
(power-down mode) has a maximum value of 200 µA at
(power-down mode) is measured with: RESET =
(active mode) is measured with: CPU clock and input clock to all peripherals running at 26.7 MHz(set by
(idle mode) is measured with: CPU clock disabled, watchdog timer disabled, input clock to all peripherals
(idle mode with slow-down mode) is measured with: CPU clock disabled, watchdog timer disabled, input
(active mode with slow-down mode) is measured with: CPU clock and input clock to all peripherals
= 5V Range
= 5V Range
V
Power Supply Current
I
DDP
I
DDP
PDP
I
I
Power Supply Current Parameters (Operating Conditions apply;
V
Power Down Current (Operating Conditions apply;
, no load on ports.
DDP
PDP
values are periodically measured at
values are measured at
DDP
values are measured at
values are measured under worst case conditions (
3)
= 5V range)
Symbol
I
I
I
I
Symbol
I
DDP
DDP
DDP
DDP
PDP
V
DDP
V
V
DDP
DDP
= 5.0 V.
, no load on ports.
= 5.5 V.
101
T
V
A
22.6
12.5
5.6
5.1
1
-
DDP
typ.
= + 25 °C and
typ.
Limit Values
Limit Values
B
,
B
, RESET =
V
), RESET =
T
1)
1)
AGND
A
= + 125 °C.
24.5
14
7.5
7.2
10
35
=
max.
max.
V
SS
V
T
V
DDP
A
, RXD/INT0 =
DDP
V
2)
2)
= + 125 °C and
DDP
= 5.0 V.
, no load on ports.
Unit Test Condition
mA
mA
mA
mA
, no load on ports.
Unit Test Condition
µA
µA
Electrical Parameters
V
3)
4)
5)
6)
T
T
V
DDP
A
A
DDP
V
= + 25 °C.
= + 85 °C.
V 1.1, 2009-03
DDP
; rest of the ports
= 5V range)
= 5.5 V).
XC864
4)
4)
5)
B
,

Related parts for SAK-XC864L-1FRI 5V AA