MCF5282CVM80 Freescale Semiconductor, MCF5282CVM80 Datasheet - Page 181

IC MPU 512K 80MHZ 256-MAPBGA

MCF5282CVM80

Manufacturer Part Number
MCF5282CVM80
Description
IC MPU 512K 80MHZ 256-MAPBGA
Manufacturer
Freescale Semiconductor
Series
MCF528xr
Datasheet

Specifications of MCF5282CVM80

Core Processor
Coldfire V2
Core Size
32-Bit
Speed
80MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, SPI, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
150
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
256-MAPBGA
Controller Family/series
ColdFire
Ram Memory Size
64KB
Embedded Interface Type
CAN, I2C, SPI, UART
No. Of Pwm Channels
8
Digital Ic Case Style
MAPBGA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5282CVM80
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
MCF5282CVM80
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Company:
Part Number:
MCF5282CVM80
Quantity:
4
Part Number:
MCF5282CVM80J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
The external clock is divided by two internally to produce the system clocks.
9.7.2
In external clock mode, the system is static and does not recognize reset until a clock is applied to EXTAL.
In PLL mode, the PLL operates in self-clocked mode (SCM) during reset until the input reference clock
to the PLL begins operating within the limits given in the electrical specifications.
If a PLL failure causes a reset, the system enters reset using the reference clock. Then the system clock
source changes to the PLL operating in SCM. If SCM is not functional, the system becomes static.
Alternately, if the LOCEN bit in SYNCR is cleared when the PLL fails, the system becomes static. If
external reset is asserted, the system cannot enter reset unless the PLL is capable of operating in SCM.
9.7.3
In normal PLL clock mode, the default system frequency is two times the reference frequency after reset.
The RFD[2:0] and MFD[2:0] bits in the SYNCR select the frequency multiplier.
When programming the PLL, do not exceed the maximum system clock frequency listed in the electrical
specifications. Use this procedure to accommodate the frequency overshoot that occurs when the MFD bits
are changed:
9.7.4
In PLL mode, the PLL synthesizes the system clocks. The PLL can multiply the reference clock frequency
by 2x to 9x, provided that the system clock frequency remains within the range listed in electrical
specifications. For example, if the reference frequency is 2 MHz, the PLL can synthesize frequencies of 4
MHz to 18 MHz. In addition, the RFD can reduce the system frequency by dividing the output of the PLL.
Freescale Semiconductor
1. Determine the appropriate value for the MFD and RFD fields in the SYNCR. The amount of jitter
2. Write a value of RFD (from step 1) + 1 to the RFD field of the SYNCR.
3. Write the MFD value from step 1 to the SYNCR.
4. Monitor the LOCK flag in SYNSR. When the PLL achieves lock, write the RFD value from step
in the system clocks can be minimized by selecting the maximum MFD factor that can be paired
with an RFD factor to provide the required frequency.
1 to the RFD field of the SYNCR. This changes the system clocks frequency to the required
frequency.
Clock Operation During Reset
System Clock Generation
PLL Operation
1
XTAL must be tied low in external clock mode when reset is asserted. If it
is not, clocks could be suspended indefinitely.
Keep the maximum system clock frequency below the limit given in the
Electrical Characteristics.
f
f
MFD ranges from 0 to 7.
RFD ranges from 0 to 7.
ref
sys
= input reference frequency
= CLKOUT frequency
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3
CAUTION
NOTE
Clock Module
9-11