Specifications of IS42S32800B-7BL

Memory Type
DRAM - Sychronous
Access Time
7ns
Page Size
256Mbit
Ic Interface Type
Parallel
Memory Case Style
BGA
No. Of Pins
90
Operating Temperature Range
0°C To +70°C
Termination Type
SMD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S32800B-7BL
Manufacturer:
ISSI
Quantity:
1 000
Part Number:
IS42S32800B-7BL
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
IS42S32800B-7BL
Manufacturer:
ISSI
Quantity:
20 000
Part Number:
IS42S32800B-7BL-TR
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
IS42S32800B-7BLI
Manufacturer:
ISSI
Quantity:
1 000
Part Number:
IS42S32800B-7BLI
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
IS42S32800B-7BLI-TR
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
I
5
IS42S32800B
Integrated Silicon Solution, Inc.
Rev. F
07/21/09
CLK
COMMAND
DQ0 - DQ3
CLK
ADDRESS
COMMAND
CAS# latency=2
t CK2 , DQ s
CAS# latency=3
t CK3 , DQ s
A write burst without the AutoPrecharge function may be interrupted by a subsequent Write, BankPrecharge/
PrechargeAll,or Read command before the end of the burst length.An interrupt coming from Write command can
occur on any clock cycle following the previous Write command (refer to the following figure).
Write command
(RAS#=”H”,CAS#=”L”,WE#=”L”,BS =Bank,A10 =”L”,A0-A8 =Column Address)
The Write command is used to write a burst of data on consecutive clock cycles from an active row in an active
bank.The bank must be active for at least tRCD(min.)before the Write command is issued.During write bursts,
the first valid data-in element will be registered coincident with the Write command.Subsequent data elements
will be registered on each successive positive clock edge (refer to the following figure).The DQs remain with high-
impedance at the end of the burst unless another command is initiated.The burst length and burst sequence are
determined by the mode register,which is already programmed.A full-page burst will continue until terminated (at
the end of the page it will wrap to column 0 and continue).
Burst Write Operation (Burst Length =4,CAS#Latency =2,3)
The first data element and the write
are registered on the same clock edge.
READ A
Col A
Bank,
T0
T0
NOP
WRITEA
DIN A 0
Read to Precharge (CAS#Latency =2,3)
T1
T1
NOP
I
DOUT A 0
DIN A 1
T2
T2
NOP
NOP
DOUT A 0
DIN A 2
T3
T3
NOP
DOUT A 1
NOP
Bank(s )
Precharge
DOUT A 2
DIN A 3
T4
T4
NOP
DOUT A 1
Extra data is masked.
don’t care
DOUT A 2
T5
T5
DOUT A 3
NOP
NOP
t
RP
T6
T6
DOUT A 3
NOP
NOP
Activate
T7
Bank,
Row
T7
NOP
I
T8
T8
NOP
NOP
®
11