CV500ETN01 Omron, CV500ETN01 Datasheet - Page 188

no-image

CV500ETN01

Manufacturer Part Number
CV500ETN01
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500ETN01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Total Number of Packets
Received (Response)
Total Number of Receive
Errors (Response)
Total Number of Packets
Sent (Response)
Total Number of Errors
Sent (Response)
Total Number of Send
Collisions (Response)
Precautions
Response Codes
7-3-4
Command Block
Response Block
Command/Response Reference
INTERNODE ECHO TEST
Address Disagreement
The address conversion method was set for automatic generation, but the
node address and the last byte of the local IP address do not agree, or other
host sections are 0.
EEPROM Error
An error occurred in the EEPROM memory in the Ethernet Unit.
The total number of packets received by the Ethernet Unit is returned.
The total number of errors detected while the Ethernet Unit was receiving is
returned. The types of error detected are short packet errors, alignment
errors, CRC errors, frame length errors (received frame: 1,515 bytes or more),
and communications controller overflow errors.
The total number of packets sent by the Ethernet Unit is returned.
The total number of packet errors detected while the Ethernet Unit was send-
ing is returned.
The number of packets damaged by 16 collisions with data from other nodes
during Ethernet Unit transmissions.
Counting of the total number of packets received, total number of receive
errors, total number of packets sent, total number of errors sent, and total
number of send collisions is discontinued when the counted value reaches the
maximum value.
Runs the echo test between specified nodes.
Command
0000
1001
Command
08 01
08 01
Response code
code
code
Response
code
1,998 bytes max.
Normal
Command too large
Test data
1,998 bytes max.
Test data
Description
Section 7-3
163

Related parts for CV500ETN01