CV500ETN01 Omron, CV500ETN01 Datasheet - Page 34

no-image

CV500ETN01

Manufacturer Part Number
CV500ETN01
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500ETN01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Improved FINS Message Communications
Transferring Data Files between Host Computers (FTP Server Function)
Additional E-mail Functions
Mail Receive Function
(Receiving Commands for
the PLC by E-mail)
E-mail File Attachment
Function
Features
The following functions have been improved over previous Ethernet Unit mod-
els. They allow the scale of the system to be increased, and can give greater
flexibility to the system configuration including the host computer.
A built-in FTP server function enables data files in the PLC to be read from a
workstation or computer with an FTP client function, and for data to be written
to the PLC. Large amounts of data can be transferred at a time from clients,
without requiring ladder programming.
With previous Ethernet Unit models (CS1W-ETN01/CS1W-ETN11/CJ1W-
ETN11), e-mail could sent only from the Ethernet Unit, and the data that could
be sent was limited to user-created ASCII text data and system data. Now the
following e-mail functions have been added.
Commands for the PLC (mail remote commands) can be written into e-mail,
and the Ethernet Unit can receive them, execute them, and send responses
by e-mail.
This function can be linked to the CS/CJ File Memory function.
• Expanded number of nodes (to 254 max., from 126 max.)
• Communications are now enabled even if the host computer's IP address
• An automatic client FINS node address allocation function now makes it
• FINS message communications are now enabled in TCP/IP (with up to 16
• Multiple FINS applications (such as the CX-Programmer) on the same
• The Ethernet Unit can automatically generate data files (6,000 words
is dynamic. (DHCP client computers can be handled, including TCP/IP
and UDP/IP.)
against access from nodes with dynamically changed IP addresses (set
to be fixed only).
possible to connect online to the PLC even if no FINS node address has
been set for the host computer.
node address was set for the host computer.
simultaneous connections), so a system can now utilize FINS message
communications in both UDP/IP and TCP/IP.
computer can now be connected online to the PLC via Ethernet (in either
TCP/IP or UDP/IP).
online to the PLC, it was impossible to connect any other at the same
time.
maximum per file) from the CPU Unit's I/O memory status, and send them
to specified e-mail addresses as e-mail attachments. It can also send pro-
gram files from the Memory Card (up to 1 MB) to specified e-mail
addresses as e-mail attachments.
Previously IP addresses for host computers could be fixed only.
Previously online connection to the PLC was possible only after a FINS
Previously only UDP/IP could be used.
For Ethernet Units with Unit Ver. 1.3 or later, the Unit can be protected
Previously when one FINS application on a computer was connected
Section 1-2
9

Related parts for CV500ETN01