CV500ETN01 Omron, CV500ETN01 Datasheet - Page 98

no-image

CV500ETN01

Manufacturer Part Number
CV500ETN01
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500ETN01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Receive Attached File Setting
Receive Command Setting
Receive Mail
Receive file with
specified extension
only
OBJ
STD
IOM
CSV
TXT
Custom 1 to 3
Receive specified com-
mand only
FileWrite
FileRead
FileDelete
FileList
UMBackup
PARAMBackup
IOMWrite
IOMRead
ChangeMode
ErrorLogRead
ErrorLogClear
MailLogRead
MailLogClear
Test
FinsSend
Item
Item
If this option is selected, only file attachments
with specified extensions is accepted with mail.
Use the checkboxes below to select which file
extensions are to be accepted. Multiple exten-
sions can be selected.
If this option is selected, an OBJ file (which can
be created using the CX-Programmer) contain-
ing all cyclic task and interrupt task programs in
the CPU Unit will be received.
If this option is selected, an STD file containing
the PLC Setup, registered I/O tables, routing
tables, Unit Setups, etc. (which can be read
from the CPU Unit using the CX-Programmer)
will be received.
If this option is selected, an IOM file containing
bit data from beginning to end of a memory
area (which can be created using the CX-Pro-
grammer) will be received.
If this option is selected, CSV files (created by
programs such as Excel) can be received.
If this option is selected, text files can be
received.
If this option is selected, files with extensions
specified by the user can be received.
If this option is selected, only specified
remote mail commands are executed.
The commands to be received can be
specified in the checkboxes below.
If checked, files can be written.
If checked, files can be read.
If checked, files can be deleted.
If checked, files can be listed.
If checked, the user program can be
backed up.
If checked, the parameter area can be
backed up.
If checked, writing to the I/O memory
area is permitted.
If checked, the I/O memory area can be
read.
If checked, the operating mode can be
changed.
If checked, the error log can be read.
If checked, the error log can be cleared. Checked
If checked, the mail log can be read.
If checked, the mail log can be cleared. Checked
If checked, the mail receive test can be
executed.
If checked, FINS commands can be
executed.
Contents
Contents
Section 3-8
Checked
Not checked
Checked
Not checked
Checked
Checked
Checked
Not checked
Checked
Not checked
Checked
Checked
Checked
Not checked
Not
checked
Checked
Default
Default
73