CV500ETN01 Omron, CV500ETN01 Datasheet - Page 209

no-image

CV500ETN01

Manufacturer Part Number
CV500ETN01
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500ETN01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Command/Response Reference
Remote TCP Port Number
(Response)
TCP Transitions
(Response)
Response Codes
7-3-21 IP ADDRESS TABLE WRITE
Command Block
Response Block
Parameters
Number of Records
(Command)
184
Specifies the TCP port number for the remote node.
Specifies the TCP connection status using the following numbers.
For details on TCP status changes, refer to Appendix C TCP Status Transi-
tions.
Writes the IP address table.
The number of records to write is specified in hexadecimal between 0000 and
0020 (0 to 32 decimal) in the command. If this value is set to 0, the IP address
table will be cleared so that no records are registered.
Command
00000000
00000001
00000002
00000003
00000004
00000005
00000006
00000007
00000008
00000009
0000000A
0000
0105
0302
1001
1002
1100
Command
27 50
27 50
Number
code
Response code
code
Response
of records
Number
code
CLOSED
LISTEN
SYN SENT
SYN RECEIVED
ESTABLISHED
CLOSE WAIT
FIN WAIT 1
CLOSING
LAST ACK
FIN WAIT 2
TIME WAIT
IP address
table records
Status
6 bytes
Normal
Node address setting error
Local IP address setting error
CPU Unit error; execution not possible.
Command too large
Command too small
Connection number not set from 1 to 16
Connection closed.
Waiting for connection.
SYN sent in active status.
SYN received and sent.
Already established.
FIN received and waiting for completion.
Completed and FIN sent.
Completed and exchanged FIN. Awaiting ACK.
FIN sent and completed. Awaiting ACK.
Completed and ACK received. Awaiting FIN.
After closing, pauses twice the maximum seg-
ment life (2MSL).
IP address
table records
6 bytes
Description
Meaning
Section 7-3