Basic Settings
48
Subnet Mask
Broadcast Settings
Example: Using the CX-Programmer to Set the IP Address to 10.3.65.1
When an IP address is set in the Unit Setup, that value is displayed in the IP
Address Display/Setting Area in the DM Area words allocated for CPU Bus
Units.
When the IP address is set by the CX-Programmer, and the defaults are used
for all other Unit settings, the settings will be as shown below.
For the subnet mask, all bits corresponding to the bits in the IP address used
as either the net number or the subnet number are set to 1, and the bits corre-
sponding to the host number are set to 0. These settings must be made when
using an address conversion method other than the IP address table method.
If no subnet mask is set, or if an illegal value is set, the following values will be
used depending on the IP address class.
With the default setting (0.0.0.0), a subnet mask corresponding to the IP
address class is used.
Set the method for specifying IP addresses when broadcasting.
IP address
Subnet mask
Broadcast settings
Baud rate
TCP/IP keep-alive
IP router table
Class A
Class B
Class C
All 1 (4.3BSD)
(Default)
All 0 (4.2BSD)
Setting
Class
Item
255.0.0.0
255.255.0.0
255.255.255.0
Broadcast with all ones for Host ID (4.3BSD specifications).
Broadcast with Host ID all zeros (4.2BSD specifications).
Subnet mask
Set by CX-Programmer.
Uses value corresponding to IP address class.
4.3BSD specifications
Auto
120 minutes
Not set. (IP routing not supported.)
Contents
Status
Section 2-9