PAXTM000 Red Lion Controls, PAXTM000 Datasheet - Page 13

Digital Multifunction Timer

PAXTM000

Manufacturer Part Number
PAXTM000
Description
Digital Multifunction Timer
Manufacturer
Red Lion Controls
Type
Timerr
Datasheet

Specifications of PAXTM000

Time Range
0.001sec To 1hr
Power Consumption
18VA
Supply Voltage Ac, Min
85V
Signal Input Type
Pulse
Supply Voltage Max
250VAC
Time Range Max
999999h
Character Size
0.56"
Accuracy
±0.01% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Digit Height
0.48
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Display Resolution
0.001 Sec. (Minimum Digit), 1 hr. (Single Digit)
Display Type
LED
Function
Timer
Humidity
0 to 85% (Max.) RH
Isolation Voltage
2300 V (RMS)
Length, Stripping
0.3 in. Wire
Memory Type
Non-Volatile EEPROM
Number Of Digits
5
Power, Rating
18 VA
Primary Type
Electronic
Range, Measurement
0 to 999999
Special Features
programmable
Standards
cULus Listed, CSA Certified
Temperature, Operating
0 to +50 °C
Termination
Cage Clamp
Torque
4.5 in.-lbs
Voltage, Range
85 to 250 VAC
Voltage, Supply
85 to 250 VAC
Four Separate Displays
Timer, Counter, Real-Time Clock and Date
Display Font Color
Red
No. Of Digits / Alpha
6
Supply Voltage Ac, Max
250V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
displays that are not “locked-out” in the Display mode. (See Module 3 for
Display Lock-out details.) A sub-menu provides Scrolling Speed selection.
that is not “locked-out” in the Display mode. (See Module 3 for Display Lock-
out details.)
currently shown display. If the RTC Time or Date is displayed, this function
applies to the Outputs assigned to the RTC, and does not Reset the actual RTC
Time or Date display. (See Module 6 for details on Output Assignment and
Output Reset with Display Reset.)
shown display. This is the factory setting for the Reset (RST) key. If the RTC
Time or Date is displayed, this function applies to the Outputs assigned to the
RTC, and does not Reset the actual RTC Time or Date display. (See Module 6
for details on Output Assignment and Output Reset with Display Reset.)
entered as
This function does not apply to the RTC Time or Date displays.
When active (maintained action), the meter continuously scrolls through all
When activated (momentary action), the meter advances to the next display
When active (maintained action), the meter continually resets only the
When activated (momentary action), the meter resets only the currently
When active (maintained action), the meter continually resets the displays
When activated (momentary action), the meter resets the displays entered as
in the sublist. Function does not apply to RTC Time or Date displays.
MOMENTARY RESET (Edge Triggered)
in the sublist. The sublist appears when the
t-dSp
C-dSP
t-dSp
C-dSP
DISPLAY SELECT (Edge Triggered)
MAINTAINED RESET (Level Active)
DISPLAY RESET (Edge Triggered)
DISPLAY SELECT (Level Active)
DISPLAY
DISPLAY
DISPLAY RESET (Level Active)
Cycle Counter
Cycle Counter
DESCRIPTION
DESCRIPTION
Timer
Timer
FACTORY
FACTORY
NO
NO
NO
NO
PAR
key is pressed.
13
entered as
Program only one user input for this function.
sublist, before performing an internal Maintained Reset on the selected
displays. This function does not apply to the RTC Time or Date displays.
sublist, before performing an internal Momentary Reset on the selected
displays. This function does not apply to the RTC Time or Date displays.
Program only one user input for this function.
entered as
event in Setpoint programming. This function does not apply to RTC Time or
Date displays. Program only one user input for this function.
display entered as
the Timing Direction (
Modules 1 and 4. (Program only one User Input per display for this function.)
This function does not apply to RTC Time or Date displays.
When active (maintained action), the meter “freezes” the display values
When activated, the meter “freezes” the display values entered as
When activated, the meter “freezes” the display values entered as
When active (maintained action), timing and counting ceases for the displays
When active (maintained action), the timing or counting direction for the
DISPLAY HOLD and RESET (Edge Triggered Reset)
DISPLAY HOLD and RESET (Level Active Reset)
in the sublist, while normal meter operation continues internally.
in the sublist. The inhibit function is not a
t-dsp
C-dsp
rtC-d
rtC-t
t-dSp
C-dSP
CHANGE DIRECTION (Level Active)
t-dSp
C-dSP
t-dSp
C-dSP
t-dSp
C-dSP
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY HOLD (Level Active)
in the sublist, will be reversed from the direction set by
INHIBIT (Level Active)
) and/or Counting Direction (
Cycle Counter
Cycle Counter
Cycle Counter
Cycle Counter
Cycle Counter
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
RTC Time
RTC Date
Timer
Timer
Timer
Timer
Timer
FACTORY
FACTORY
FACTORY
FACTORY
FACTORY
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
) parameters in
or
in the
in the

Related parts for PAXTM000