PAXTM000 Red Lion Controls, PAXTM000 Datasheet - Page 18

Digital Multifunction Timer

PAXTM000

Manufacturer Part Number
PAXTM000
Description
Digital Multifunction Timer
Manufacturer
Red Lion Controls
Type
Timerr
Datasheet

Specifications of PAXTM000

Time Range
0.001sec To 1hr
Power Consumption
18VA
Supply Voltage Ac, Min
85V
Signal Input Type
Pulse
Supply Voltage Max
250VAC
Time Range Max
999999h
Character Size
0.56"
Accuracy
±0.01% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Digit Height
0.48
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Display Resolution
0.001 Sec. (Minimum Digit), 1 hr. (Single Digit)
Display Type
LED
Function
Timer
Humidity
0 to 85% (Max.) RH
Isolation Voltage
2300 V (RMS)
Length, Stripping
0.3 in. Wire
Memory Type
Non-Volatile EEPROM
Number Of Digits
5
Power, Rating
18 VA
Primary Type
Electronic
Range, Measurement
0 to 999999
Special Features
programmable
Standards
cULus Listed, CSA Certified
Temperature, Operating
0 to +50 °C
Termination
Cage Clamp
Torque
4.5 in.-lbs
Voltage, Range
85 to 250 VAC
Voltage, Supply
85 to 250 VAC
Four Separate Displays
Timer, Counter, Real-Time Clock and Date
Display Font Color
Red
No. Of Digits / Alpha
6
Supply Voltage Ac, Max
250V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Parameters. This programming module can only be accessed if a Setpoint card
is installed. Depending on the card installed, there will be two or four Setpoint
outputs available. The Setpoint Assignment and Setpoint Action parameters
determine the applicable Setpoint features, and dictate which subsequent
parameters will appear for the Setpoint being programmed.
Quad Setpoint plug-in cards. Discard the separate bulletin when using Setpoint
plug-in cards with the PAXCK and PAXTM.
the parameters for that particular Setpoint. The “ ” in the following parameter
displays, reflects the chosen Setpoint number (1 thru 4). After the chosen
Setpoint is programmed, the display returns to
Setpoint to be programmed and continue this sequence for each Setpoint. Select
Cycle Counter (
Clock Time display (
Real-Time Clock option card is installed.)
However, the output can still be activated (set) and deactivated (reset) by
various “events”. Such events include the Timer starting or stopping, or another
Setpoint output turning On or Off. The output can also be set and reset through
a User Input function or through serial communications.
Output activation is controlled by the SETPOINT ON parameter setting.
to
6.6 MODULE 6 - S
This module can only be accessed if a Setpoint Card is installed.
Module 6 is the programming module for the Setpoint (Alarm) Output
This section of the bulletin replaces the bulletin shipped with the Dual and
Select the Setpoint (alarm) output to be programmed. This provides access to
Select the meter display to which the Setpoint is assigned: Timer (
By selecting
This parameter determines the mode for output deactivation as shown below.
The
to exit the module.
LAtCH
t-OUt
ON-OFF
.
DISPLAY
and
Latched Output Mode
Timed Output Mode
On-Off Output Mode
, the Setpoint is not assigned to a specific display.
), Real-Time Clock Date display (
SETPOINT ASSIGNMENT
selections are not available when Setpoint is assigned
SETPOINT SELECT
SETPOINT ACTION
). (The
DESCRIPTION
and
apply to Quad Setpoint cards only.
and
At Reset (Manual or Automatic)
Based on “Setpoint Off” Setting
After “Time-Out Value” Elapses
ETPOINT
selections only appear if a
OUTPUT DEACTIVATES
. Select the next
) or Real-Time
PARAMETER MENU
(A
),
LARM
18
activation can occur at a specific Setpoint Value (
various “events”, as shown in the parameter list. Such events include the Timer
starting (
another Setpoint output to turn On or Off. When programmed for an event, the
Setpoint must not be used as the Setpoint On event for another Setpoint.
Setpoint value is based on the meter display to which the Setpoint is assigned
(
entered in the same format as the assigned display. When assigned to the Real-
Time Clock Date Display (
format (
the Setpoint value is always entered in
AM/PM selection). In Setpoint One-shot mode (See Daily On Occurrence), the
One-shot Setpoint is enabled (armed) by scrolling the AM/PM digit until the 2nd
digit decimal point is lit.
when deactivated. Reverse Output Logic (
activated and “on” when deactivated.
is programmed for On-Off Output mode (
determines when the Setpoint output will deactivate. Output deactivation can
occur at a specific Setpoint Off Value (
“events”, as shown in the parameter list. Such events include the Timer starting
(
Setpoint output to turn On or Off. When programmed for an event, the Setpoint
must not be used as the Setpoint Off event for another Setpoint.
entered. The Setpoint Off value is based on the meter display to which the
Setpoint is assigned (
value is entered in the same format as the assigned display. When assigned to
the Real-Time Clock Date Display (
month.day.year format (
Display (
with AM/PM selection).
This parameter determines when the Setpoint output will activate. Output
Selecting
Normal Output Logic (
The Setpoint Off parameter only appears when the Setpoint Action (
Selecting
) P
). When assigned to the Timer or Cycle Counter, the Setpoint value is
) or stopping (
ARAMETERS
). When assigned to the Real-Time Clock Time Display (
), the value is always entered in
) or stopping (
displays a sub-menu where the Setpoint value is entered. The
will display a sub-menu where the Setpoint Off value is
). When assigned to the Timer or Cycle Counter, the
OUTPUT LOGIC
SETPOINT OFF
) turns the output “on” when activated and “off”
SETPOINT ON
), or by the action (event) that causes another
). When assigned to the Real-Time Clock Time
), the date value is entered in month.day.year
), or by the action (event) that causes
to
(
to
), the date value is entered in
) or can be triggered by various
) turns the output “off” when
). In this mode, this parameter
format (Hours-Minutes with
= Setpoint Number 1 thru 4
) or can be triggered by
format (Hours-Minutes
)
),
)

Related parts for PAXTM000