PAXTM000 Red Lion Controls, PAXTM000 Datasheet - Page 16

Digital Multifunction Timer

PAXTM000

Manufacturer Part Number
PAXTM000
Description
Digital Multifunction Timer
Manufacturer
Red Lion Controls
Type
Timerr
Datasheet

Specifications of PAXTM000

Time Range
0.001sec To 1hr
Power Consumption
18VA
Supply Voltage Ac, Min
85V
Signal Input Type
Pulse
Supply Voltage Max
250VAC
Time Range Max
999999h
Character Size
0.56"
Accuracy
±0.01% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Digit Height
0.48
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Display Resolution
0.001 Sec. (Minimum Digit), 1 hr. (Single Digit)
Display Type
LED
Function
Timer
Humidity
0 to 85% (Max.) RH
Isolation Voltage
2300 V (RMS)
Length, Stripping
0.3 in. Wire
Memory Type
Non-Volatile EEPROM
Number Of Digits
5
Power, Rating
18 VA
Primary Type
Electronic
Range, Measurement
0 to 999999
Special Features
programmable
Standards
cULus Listed, CSA Certified
Temperature, Operating
0 to +50 °C
Termination
Cage Clamp
Torque
4.5 in.-lbs
Voltage, Range
85 to 250 VAC
Voltage, Supply
85 to 250 VAC
Four Separate Displays
Timer, Counter, Real-Time Clock and Date
Display Font Color
Red
No. Of Digits / Alpha
6
Supply Voltage Ac, Max
250V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Display Mode, the CNT annunciator indicates the Cycle Counter display is
currently being shown. An EXCHANGE PARAMETER LISTS feature, which
includes the Cycle Counter Start and Stop Values, is explained in Module 2.
subtracted from the Cycle Counter. Select
being used, which will exit the module and bypass the remaining parameters.
activated. When selected as the count source, User Input 1 can still be
programmed to perform a User Function described in Module 2, if desired. In
this case, the Cycle Counter would be counting the number of times the
particular User Function occurred.
or automatic reset occurs. (See Module 6 for programming Automatic Resets.)
either activates or deactivates. These selections only appear when a Setpoint
Card is installed. O3 and O4 selections only appear for Quad Setpoint cards.
These modes cover a variety of timing applications frequently encountered in
industrial control processes. When using a Predefined mode, the operator needs
only to set the actual Setpoint On/Off or Time-out values for the particular
application. However, each programming parameter will still be accessible, in
order to make modifications to the predefined settings if desired.
6.4 MODULE 4 - C
6.5 MODULE 5 - T
This module can only be accessed if a Setpoint Card is installed.
* Only the value parameters which apply to the selected mode will appear.
Module 4 is the programming module for the Cycle Counter Parameters. In the
This parameter selects the source from which a count is added to or
When
The Timer Reset (
The Output ON/OFF selections generate a count when the chosen output
Counting direction can be reversed through a User Input. (See Module 2.)
This parameter is used to select Predefined Operating Modes for the Timer.
CYCLE COUNTER COUNTING DIRECTION
PREDEFINED TIMER OPERATING MODE
CYCLE COUNTER COUNT SOURCE
is selected, a count is generated each time the User 1 Input is
rEPEAt
dLYINt
INt-L
INt-E
ON-dLY
OF-dLY
) selection generates a count when either a manual
- On-Delay Timing
- Off-Delay Timing
- Repeat Cycle Timing
- On-Delay/Interval Timing
- Interval Timing (Level Triggered)
- Interval Timing (Edge Triggered)
if the Cycle Counter is not
IMER
YCLE
C
PARAMETER MENU
O
PARAMETER MENU
OUNTER
PERATING
16
occurs. Non-zero values are normally used for “down counting” applications,
but they can also provide an “offset” value when counting up.
the operation of the Timer. Selecting
the Stop Value can be set or changed. The Stop condition is cleared when a
Cycle Counter Reset occurs. Select
relation to Start and Reset signals applied to the Timer inputs. (See timing
diagrams which follow.) When a selection other than
parameters for Setpoint 1 (
implement the selected operating mode. For some modes, parameters in
Modules 1 and 2 are also automatically configured to properly implement the
predefined mode. Refer to the chart shown with the timing diagrams for the
specific parameters loaded for each predefined mode. Also, note the specific
external wiring or plug jumper settings required for some modes.
be entered directly in Module 5 after selecting the operating mode. Only the
value parameters which apply to the selected mode are displayed. These values
can also be entered through Module 6, Setpoint (Alarm) Parameters, if desired.
parameters must all be individually programmed for the particular application.
P
The Cycle Counter returns to this value whenever a Cycle Counter Reset
The Cycle Counter stops counting when this value is reached, regardless of
The Cycle Counter can be programmed to Reset at each meter power-up.
The Predefined modes control the activation and deactivation of Output 1, in
The Setpoint On/Off or Time-out values for the specific application should
Select
ARAMETERS
M
CYCLE COUNTER RESET AT POWER-UP
ODES
if not using a Predefined Operating Mode, in which case Setpoint
CYCLE COUNTER START VALUE
CYCLE COUNTER STOP VALUE
(
) in Module 6 are automatically configured to
(
if a Stop Value is not used.
to
to
will display the
)
999
)
sub-menu where
is chosen, the