PAXTM000 Red Lion Controls, PAXTM000 Datasheet - Page 26

Digital Multifunction Timer

PAXTM000

Manufacturer Part Number
PAXTM000
Description
Digital Multifunction Timer
Manufacturer
Red Lion Controls
Type
Timerr
Datasheet

Specifications of PAXTM000

Time Range
0.001sec To 1hr
Power Consumption
18VA
Supply Voltage Ac, Min
85V
Signal Input Type
Pulse
Supply Voltage Max
250VAC
Time Range Max
999999h
Character Size
0.56"
Accuracy
±0.01% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Digit Height
0.48
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Display Resolution
0.001 Sec. (Minimum Digit), 1 hr. (Single Digit)
Display Type
LED
Function
Timer
Humidity
0 to 85% (Max.) RH
Isolation Voltage
2300 V (RMS)
Length, Stripping
0.3 in. Wire
Memory Type
Non-Volatile EEPROM
Number Of Digits
5
Power, Rating
18 VA
Primary Type
Electronic
Range, Measurement
0 to 999999
Special Features
programmable
Standards
cULus Listed, CSA Certified
Temperature, Operating
0 to +50 °C
Termination
Cage Clamp
Torque
4.5 in.-lbs
Voltage, Range
85 to 250 VAC
Voltage, Supply
85 to 250 VAC
Four Separate Displays
Timer, Counter, Real-Time Clock and Date
Display Font Color
Red
No. Of Digits / Alpha
6
Supply Voltage Ac, Max
250V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PARAMETER VALUE CHART
PAXCK Clock Timer
* See Module 2, Exchanging Parameter Lists, for details on programming this value.
1-INP
2-FNC
rANGE
INP OP
FILtEr
t dir
t Strt
t StOP
VaLUE
FLASH
InP-UP
t p-UP
USEr-1
USEr-2
USEr-3
F1
F2
rSt
SEC-F1
SEC-F2
Shaded areas are model dependent.
Shaded areas are model dependent.
DISPLAY
DISPLAY
Timer Input Parameters
User Input and Function Key Parameters
TIMER RANGE
TIMER INPUT OPERATION
TIMER INPUT FILTERING
TIMING DIRECTION
TIMER START VALUE (A)
TIMER START VALUE (B)*
TIMER STOP (A & B*)
TIMER STOP VALUE (A)
TIMER STOP VALUE (B)*
FLASH TIMER ANNUNCIATOR
TIMER INPUT STATE AT POWER-UP
TIMER RESET AT POWER-UP
USER INPUT 1
USER INPUT 2
USER INPUT 3
FUNCTION KEY 1
FUNCTION KEY 2
RESET KEY
SECONDARY FUNCTION KEY F1
SECONDARY FUNCTION KEY F2
PARAMETER
PARAMETER
SSSSSS
drSt-E
FACTORY
FACTORY
SETTING
SETTING
LEVEL
NO
NO
NO
NO
NO
NO
NO
NO
USER SETTING
USER SETTING
Programmer ________________ Date ________
Meter# _____________ Security Code __________
26
5-OPEr
3-LOC
4-CNt
C Src
C dir
C Strt
C StOP
VALUE
C p-UP
t OPEr
SP-1
SPOF-1
tOUt-1
t-dSP
C-dSP
rtC-d
rtC-t
Sp-1
SP0F-1
tOUt-1
Sp-2
Sp0f-2
tOUt-2
sp-3
sp0f-3
tOUt-3
sp-4
sp0f-4
tOUt-4
t Strt
t StOP
C Strt
C StOP
SEt-t
COdE
DISPLAY
DISPLAY
DISPLAY
Display and Program Lock-out Parameters
Cycle Counter Parameters
PREDEFINED TIMER OPER. MODE
SETPOINT 1 ON VALUE
SETPOINT 1 OFF VALUE
SETPOINT 1 TIME-OUT VALUE
Timer Operating Modes
CYCLE COUNTER COUNT SOURCE
CYC. CNTR. COUNTING DIRECTION
CYCLE COUNTER START VALUE (A)
CYCLE COUNTER START VALUE (B)*
CYCLE COUNTER STOP (A & B*)
CYCLE COUNTER STOP VALUE (A)
CYCLE COUNTER STOP VALUE (B)*
CYC. CNTR. RESET AT POWER-UP
TIMER DISPLAY LOCK-OUT
CYCLE COUNT DISPLAY LOCK-OUT
RTC DATE DISPLAY LOCK-OUT
RTC TIME DISPLAY LOCK-OUT
SP1 ON VALUE ACCESS
SP1 OFF VALUE ACCESS
SP1 TIME-OUT VALUE ACCESS
SP2 ON VALUE ACCESS
SP2 OFF VALUE ACCESS
SP2 TIME-OUT VALUE ACCESS
SP3 ON VALUE ACCESS
SP3 OFF VALUE ACCESS
SP3 TIME-OUT VALUE ACCESS
SP4 ON VALUE ACCESS
SP4 OFF VALUE ACCESS
SP4 TIME-OUT VALUE ACCESS
TIMER START VALUE ACCESS
TIMER STOP ACCESS
COUNTER START VALUE ACCESS
COUNTER STOP VALUE ACCESS
RTC TIME SETTING ACCESS
SECURITY CODE
PARAMETER
PARAMETER
PARAMETER
000100
FACTORY
SETTING
000000
000000
000000
OOOOOO
FACTORY
FACTORY
SETTING
SETTING
NONE
rEd
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
000
NO
UP
NO
NO
USER SETTING
USER SETTING
USER SETTING