CV500-ZS3AT1-EV2 Omron, CV500-ZS3AT1-EV2 Datasheet - Page 34

no-image

CV500-ZS3AT1-EV2

Manufacturer Part Number
CV500-ZS3AT1-EV2
Description
C.V SOFTWARE 3.5in DISK
Manufacturer
Omron
Datasheet

Specifications of CV500-ZS3AT1-EV2

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
System Configuration
Mounting Locations
16-/32-/64-point
I/O Units
Service Power
Supplies
Interrupt Input
Units
C500 Special I/O
Units
BASIC Units
Temperature
Controller Data
Link Unit
Personal
Computer Units
SYSMAC NET
Link Units
SYSMAC LINK
Units
SYSMAC BUS/2
Remote I/O
Master Units
Ethernet Units
CompoBus/D
Master Unit
SYSMAC BUS
Remote I/O
Master Units
SYSMAC BUS
I/O Link Units
Unit
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Rack
CPU
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Expansion
CPU Rack
The following table below summarizes the Units that can be mounted to CPU,
Expansion CPU, Expansion I/O, and Slave Racks. For detailed information
about the Units listed below, refer to the operation manual for the individual Unit.
Yes
Yes
No
Yes
No
No
No
No
No
No
No
No
Yes
Yes
Expansion
I/O Racks
Yes
Yes
No
Yes
The following cannot be
mounted to SYSMAC
BUS/2 Slave Racks:
NC103, NC221, NC222,
CP131, FZ001, PID01,
and MCC01.
The following cannot be
mounted to SYSMAC
BUS Slave Racks:
NC221, NC222, CT041,
and FZ001.
All other Special I/O Units
can be mounted.
No
No
No
No
No
No
No
No
No
No
Slave Racks (CV- or
C-series)
---
---
Up to 4 Units can be mounted.
When mounting to the Expansion
CPU Rack, set the rack number
to 1.
Up to 8 of the following Units can
be mounted: Analog Input, Analog
Output, High-speed Counter, PID,
Position Control, Magnetic Card,
ASCII, ID Sensor, and Ladder
Program I/O. Position Control
Units, NC103-E, and PID Units
use 2 slots.
READ(190)/WRIT(191) cannot be
used with Units mounted to
SYSMAC BUS Slave Racks.
Up to 16 CPU Bus Units can be
used with each PC, including 2
Remote I/O Master Units for the
CV500 or CVM1-CPU01-EV2 or 4
for the CV1000 CV2000
for the CV1000, CV2000,
CVM1-CPU11-EV2, or
CVM1-CPU21-EV2, up to a 4
CVM1-CPU21-EV2, u to a 4
each of the SYSMAC NET Link,
SYSMAC LINK Units, Host Link
U it
Unit, or Ethernet Unit, and 1
CompoBus/D Master Unit.
A P
A Personal Computer Unit
requires 4 slots.
Up to 4 Units can be mounted to
a CV500 or CVM1-CPU01-EV2
and eight Units to a CV1000,
CV2000, CVM1-CPU11-EV2, or
CVM1-CPU21-EV2.
I/O cannot be set to 16 input/16
output.
d i h
Eth
l C
Remarks
h PC i
t U it
Section 2-1
t
,
U it
l di
d 1
2
21

Related parts for CV500-ZS3AT1-EV2