CS1D-BC042D Omron, CS1D-BC042D Datasheet - Page 253

no-image

CS1D-BC042D

Manufacturer Part Number
CS1D-BC042D
Description
CS1D Dual CPU Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-BC042D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specific PLC Setup Settings
Online Replacement Settings
Enabling Unit Removal without a Programming Device
Enabling Unit Removal/Addition of Units without a Programming Device
218
131
132
Word
Word
Programming
Programming
Address in
Address in
Console
Console
0 to 15
8 to 15
Bit(s)
Bit(s)
Value other than
5AA5 hex: Online
replacement can be
performed with a
Programming
Device only. (An I/O
bus error will occur if
the Unit is removed
without using a PLC
Programming
Device.)
5AA5 hex: Enable
Unit removal with-
out a Programming
Device.
Default: 0000
Value other than AA
hex: Online replace-
ment can be per-
formed with a
Programming
Device only. (An I/O
bus error will occur if
the Unit is removed
without using a PLC
Programming
Device.)
AA hex: Enable Unit
removal/addition
without a Program-
ming Device.
Default: 00
Note
Note
Settings
Settings
1. This setting can be used only in Duplex CPU Units with Unit Ver. 1.2 and
2. This setting can be selected with CX-Programmer version 6.1 or higher.
1. This setting is supported only in CS1D CPU Units with unit version 1.3 or
2. As of October 2006, this setting can be selected with the Programming
later.
later and a Duplex CPU, Dual I/O Expansion System.
If the Removal/Addition of Units without a Programming Device function is
selected in a Duplex CPU, Single I/O Expansion System, the function will
operate as the earlier Unit Removal of without a Programming Device func-
tion.
Console only. The setting will be added to the CX-Programmer in the next
version upgrade. The setting will be added to CX-Programmer version 7.0
when its functions are expanded by auto-update.
This setting determines if a Unit can be
removed without a PLC Programming
Device.
5AA5 hex: When Unit removal without Pro-
gramming Device is enabled, I/O bus errors
caused by Unit failures are treated as non-
fatal errors.
More than one Unit can be replaced at a
time.
A fatal error will occur if an Expansion Rack
Cable, Backplane, Duplex Unit, or Long-dis-
tance Expansion I/O Rack is removed or
fails.
This setting determines if Units can be
removed and added without a PLC Pro-
gramming Device. With this setting, opera-
tion will recover automatically even if a Unit
is added.
AA hex: When Removal/Addition of Units
without a Programming Device is enabled,
I/O bus errors caused by Unit failures are
treated as non-fatal errors.
More than one Unit can be replaced at a
time.
A fatal error will occur if an Expansion Rack
Cable, Backplane, Duplex Unit, or Long-dis-
tance Expansion I/O Rack is removed or
fails.
Function
Function
A09911
A80015
A80215
A09911
A80015
A80215
flags and
flags and
Related
Related
words
words
Section 6-2
Every cycle
Every cycle
ting’s effec-
ting’s effec-
New set-
New set-
tiveness
tiveness

Related parts for CS1D-BC042D