COM20022I3V-HD SMSC, COM20022I3V-HD Datasheet - Page 11

no-image

COM20022I3V-HD

Manufacturer Part Number
COM20022I3V-HD
Description
Network Controller & Processor ICs ARCNET Contrllr
Manufacturer
SMSC
Datasheet

Specifications of COM20022I3V-HD

Data Rate
10 Mbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
TQFP-48
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
10 Mbps ARCNET (ANSI 878.1) Controller with 2Kx8 On-Board RAM
Datasheet
Chapter 4
4.1
4.2
4.2.1
SMSC COM20022I 3V
Network Protocol
Communication on the network is based on a token passing protocol. Establishment of the network
configuration and management of the network protocol are handled entirely by the COM20022I 3V's
internal microcoded sequencer. A processor or intelligent peripheral transmits data by simply loading a
data packet and its destination ID into the COM20022I 3V's internal RAM buffer, and issuing a command
to enable the transmitter. When the COM20022I 3V next receives the token, it verifies that the receiving
node is ready by first transmitting a FREE BUFFER ENQUIRY message. If the receiving node transmits
an ACKnowledge message, the data packet is transmitted followed by a 16-bit CRC. If the receiving node
cannot accept the packet (typically its receiver is inhibited), it transmits a Negative AcKnowledge message
and the transmitter passes the token. Once it has been established that the receiving node can accept the
packet and transmission is complete, the receiving node verifies the packet. If the packet is received
successfully, the receiving node transmits an ACKnowledge message (or nothing if it is not received
successfully) allowing the transmitter to set the appropriate status bits to indicate successful or unsuccessful
delivery of the packet. An interrupt mask permits the COM20022I 3V to generate an interrupt to the
processor when selected status bits become true. Figure 3.1 is a flow chart illustrating the internal operation
of the COM20022I 3V connected to a 20 MHz crystal oscillator.
Data Rates
The COM20022I 3V is capable of supporting data rates from 156.25 Kbps to 10 Mbps. The following
protocol description assumes a 10 Mbps data rate. To attain the faster data rates, the clock frequency may
be doubled or quadrupled by the internal clock multiplier (see next section). For slower data rates, an
internal clock divider scales down the clock frequency. Thus all timeout values are scaled as shown in the
following table:
Example: IDLE LINE Timeout @ 10 Mbps = 20.5 μs. IDLE LINE Timeout for 156.2 Kbps is 20.5 μs * 64 =
1.3 ms
Selecting Clock Frequencies Above 2.5 Mbps
To realize a 10 Mbps network, an external 80 MHz clock must be input. However, since 80 MHz is the
frequency of FM radio band, it is not practical for use for noise emission reasons. Therefore, higher
frequency clocks are generated from the 20 MHz crystal as selected through two bits in the Setup2
register, CKUP[1,0] as shown below. The selected clock is supplied to the ARCNET controller.
FREQUENCY
INTERNAL
CLOCK
80 MHz
40 MHz
20 MHz
Protocol Description
PRESCALER
Div. by 128
Div. by 16
Div. by 32
Div. by 64
Div. by 8
Div. by 8
Div. by 8
CLOCK
DATASHEET
DATA RATE
156.25 Kbps
Page 11
312.5 Kbps
1.25 Mbps
625 Kbps
2.5 Mbps
10 Mbps
5 Mbps
FACTOR (MULTIPLY BY)
TIMEOUT SCALING
16
32
64
1
2
4
8
Revision 02-27-06