2.4.6
Datasheet
Document #: 249276
Revision #: 002
Rev. Date: 07/20/01
Power-Up
H/W Reset
H/W Power-Down Recovery
S/W Power-Down Recovery
S/W Reset
Table 20. Initialization Modes
Mode
Determining Link State
The LXT1000 and its link partner determine the type of link established through one of three
methods:
Auto-negotiation is the only method allowed by the 802.3ab standard for establishing a
1000BASE-T link, although forced operation can be used for test purposes. (See
Information” on page
sections discuss each in greater detail.
Figure 16
negotiation is enabled. If not, the LXT1000 forces operation as directed. If auto-negotiation is
enabled, the LXT1000 begins transmitting Fast Link Pulses (FLPs) and receiving FLPs from its
link partner. If FLPs are received by the LXT1000, auto-negotiation proceeds. It also can receive
100BASE-TX MLT3 and 10BASE-T Normal Link Pulses (NLPs). If either MLT3 or NLPs are
received, it aborts FLP transmission and immediately brings up the corresponding half-duplex link.
Auto-Negotiation
Parallel Detection
Forced Operation
provides an overview of link establishment. First the LXT1000 checks if auto-
Functions
Initializes
PLL and
Analog
Yes
Yes
Yes
Yes
No
70.) For 10/100 links, any of the three methods can be used. Following
State Machines
Functions and
Initializes
Digital
Yes
Yes
Yes
Yes
Yes
RX_CLK
TX_CLK
and
Yes
Yes
Gigabit Ethernet Transceiver — LXT1000
No
No
No
Registers
Access
Yes
Yes
MII
No
No
No
H/W Configuration Balls
“Test
Re-Read
Yes
Yes
Yes
Yes
No
39