SC2200UFH-300 AMD (ADVANCED MICRO DEVICES), SC2200UFH-300 Datasheet - Page 249

no-image

SC2200UFH-300

Manufacturer Part Number
SC2200UFH-300
Description
Manufacturer
AMD (ADVANCED MICRO DEVICES)
Datasheet

Specifications of SC2200UFH-300

Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC2200UFH-300F
Manufacturer:
NSC
Quantity:
201
Core Logic Module - SMI Status and ACPI Registers - Function 1
AMD Geode™ SC2200 Processor Data Book
Bit
10
9
8
7
6
5
4
Description
GPWIO2_STS. Indicates if PME was caused by activity on GPWIO2.
0: No.
1: Yes.
Write 1 to clear.
For the PME to generate an SCI:
1)
2)
If F1BAR1+I/O Offset 15h[6] = 1 it overrides these settings and GPWIO2 generates an SMI and the status is reported in
F1BAR0+00h/02h[0].
GPWIO1_STS. Indicates if PME was caused by activity on GPWIO1.
0: No.
1: Yes.
Write 1 to clear.
For the PME to generate an SCI:
1)
2)
If F1BAR1+I/O Offset 15h[5] = 1 it overrides these settings and GPWIO1 generates an SMI and the status is reported in
F1BAR0+00h/02h[0].
GPWIO0_STS. Indicates if PME was caused by activity on GPWIO0.
0: No.
1: Yes.
Write 1 to clear.
For the PME to generate an SCI:
1)
2)
If F1BAR1+I/O Offset 15h[4] = 1 it overrides these settings and GPWIO0 generates an SMI and the status is reported in
F1BAR0+00h/02h[0].
Reserved. Must be set to 0.
USB_STS. Indicates if PME was caused by a USB interrupt event.
0: No.
1: Yes.
Write 1 to clear.
For the PME to generate an SCI, set F1BAR1+I/O Offset 12h[6] = 1 and F1BAR1+I/O Offset 0Ch[0] = 1. (See Note 2 in the
general description of this register above.)
THRM_STS. Indicates if PME was caused by activity on THRM#.
0: No.
1: Yes.
Write 1 to clear.
For the PME to generate an SCI, set F1BAR1+I/O Offset 12h[5] = 1 and F1BAR1+I/O Offset 0Ch[0] = 1, (See Note 2 in the
general description of this register above.)
SMI_STS. Indicates if PME was caused by activity on the internal SMI# signal.
0: No.
1: Yes.
Write 1 to clear.
For the PME to generate an SCI, set F1BAR1+I/O Offset 12h[4] = 1 and F1BAR1+I/O Offset 0Ch[0] = 1. (See Note 2 in the
general description of this register above.)
Ensure that GPWIO2 is enabled as an input (F1BAR1+I/O Offset 15h[2] = 0).
Set F1BAR1+I/O Offset 12h[10] = 1 and F1BAR1+I/O Offset 0Ch[0] = 1. (See Note 2 in the general description of this
register above.)
Ensure that GPWIO1 is enabled as an input (F1BAR1+I/O Offset 15h[1] = 0)
Set F1BAR1+I/O Offset 12h[9] = 1 and F1BAR1+I/O Offset 0Ch[0] = 1. (See Note 2 in the general description of this
register above.)
Ensure that GPWIO0 is enabled as an input (F1BAR1+I/O Offset 15h[0] = 0).
Set F1BAR1+I/O Offset 12h[8] = 1 and F1BAR1+I/O Offset 0Ch[0] = 1. (See Note 2 in the general description of this
register above).
Table 6-34. F1BAR1+I/O Offset: ACPI Support Registers (Continued)
32580B
259

Related parts for SC2200UFH-300