NUC130VE3CN Nuvoton Technology Corporation of America, NUC130VE3CN Datasheet - Page 259

no-image

NUC130VE3CN

Manufacturer Part Number
NUC130VE3CN
Description
IC MCU 32BIT 128KB FLASH 100LQFP
Manufacturer
Nuvoton Technology Corporation of America
Series
NuMicro™ NUC100r
Datasheets

Specifications of NUC130VE3CN

Core Processor
ARM Cortex-M0
Core Size
32-Bit
Speed
50MHz
Connectivity
CAN, EBI/EMI, I²C, IrDA, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, I²S, POR, PWM, WDT
Number Of I /o
80
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Eeprom Size
-
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
2.5 V ~ 5.5 V
Data Converters
A/D 8x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-LQFP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NUC130VE3CN
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
Part Number:
NUC130VE3CN
Manufacturer:
NUVOTON
Quantity:
20 000
5.8.4
5.8.4.1
5.8.4.2
5.8.4.3
5.8.4.4
5.8.4.5
5.8.4.6
Due to clock difference between RTC clock and system clock, when user write new data to any
one of the registers, the register will not be updated until 2 RTC clocks later (60us).
In addition, user must be aware that RTC controller does not check whether loaded data is out of
bounds or not. RTC does not check rationality between DWR and CLR either.
When RTC block is power on, RTC is at reset state. User has to write a number (0xa5eb1357) to
INIR to make RTC leaving reset state. Once the INIR is written as 0xa5eb1357, the RTC will be in
un-reset state permanently.
Register AER bit 15~0 is served as RTC read/write password to protect RTC registers. AER bit
15~0 has to be set as 0xA965 to enable access restriction. Once it is set, it will take effect at least
512 RTC clocks (about 15ms). Programmer can read RTC enabled status flag in AER.ENF to
check whether if RTC controller starts operating or not.
The RTC FCR allows software to make digital compensation to a clock input. The frequency of
clock input must be in the range from 32776 Hz to 32761 Hz. User can utilize a frequency counter
to measure RTC clock on one of GPIO pin during manufacture, and store the value in Flash
memory for retrieval when the product is first power on. Following are the compensation
examples for higher or lower frequency clock input.
Example 1:
Example 2
TLR and CLR are used to load the time and calendar. TAR and CAR are used for alarm. They are
all represented by BCD.
The 12/24 hour time scale selection depends on TSSR bit 0.
Function Description
Access to RTC register
RTC Initiation
RTC Read/Write Enable
Frequency Compensation
Time and Calendar counter
12/24 hour Time Scale Selection
NuMicro™ NUC130/NUC140 Technical Reference Manual
Frequency counter measurement : 32773.65 Hz ( > 32768 Hz)
Integer part: 32773 => 0x8005
FCR.Integer = 0x05 – 0x01 + 0x08 = 0x0c
Fraction part: 0.65 x 60 = 39 => 0x27
FCR.Fraction = 0x27
Frequency counter measurement : 32765.27
Integer part: 32765 => 0x7FFD
FCR.Integer = 0x0A – 0x01 – 0x08 = 0x04
Fraction part: 0.27 x 60 = 16.2=> 0x10
FCR.Fraction = 0x10
- 259 -
Publication Release Date: June 14, 2011
Hz (
32768 Hz)
Revision V2.01