IDT82P2816BB IDT, Integrated Device Technology Inc, IDT82P2816BB Datasheet - Page 54

no-image

IDT82P2816BB

Manufacturer Part Number
IDT82P2816BB
Description
IC LIU T1/J1/E1 16+1CH 416-PBGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT82P2816BB

Function
Line Interface Unit (LIU)
Interface
E1, J1, T1
Number Of Circuits
1
Voltage - Supply
1.8V, 3.3V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
*
Includes
Defect and Alarm Detection, Driver Over-Current Detection and Protection, LLOS Detection, PRBSARB / IB Detection and Generation
Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Current - Supply
-
Power (watts)
-
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
82P2816BB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82P2816BB
Manufacturer:
ADI
Quantity:
6 358
Part Number:
IDT82P2816BB
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2816BBG
Manufacturer:
IDT Integrated Device Technolo
Quantity:
135
Part Number:
IDT82P2816BBG
Manufacturer:
IDT
Quantity:
70
Part Number:
IDT82P2816BBG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
3.5.9
the other 16 channels, or it can be used as a monitoring channel.
Channel 0 supports G.772 Monitoring and Jitter Measurement.
3.5.9.1 G.772 Monitoring
mitter of the other 16 channels can be monitored by channel 0 (as
shown in Figure-33).
(b5~0, MON) is not ‘0’), the registers of the receiver of channel 0 should
be the same as those of the selected receiver /transmitter except the
line interface related registers.
Functional Description
IDT82P2816
Channel 0 is a special channel. It can be used in normal operation as
Selected by the MON[5:0] bits (b5~0, MON), any receiver or trans-
When the G.772 Monitoring is implemented (the MON[5:0] bits
CHANNEL 0 MONITORING
RRINGn
RRING0
TRINGn
TRING0
RTIPn
RTIP0
TTIPn
TTIP0
G.772 Monitoring
Figure-33 G.772 Monitoring
Remaining Channels
16(+1) CHANNEL HIGH-DENSITY T1/E1/J1 LINE INTERFACE UNIT
Any of the
54
CH 0
switches to External Impedance Matching mode automatically, and the
setting in the R_TERM[2:0] bits (b2~0, RCF0,...) of channel 0 is ignored.
data is received from the selected path and the operation of the moni-
tored path is not effected.
Recovery of monitoring channel (channel 0). The monitored clock can
output on RCLK0. The monitored data can be observed digitally on the
output pin of RCLK0, RD0/RDP0 and RDN0. LOS detector is still in use
in channel 0 for the monitored signal.
back. The signal which is being monitored will output on TTIP0 and
TRING0. The output signal can then be connected to a standard test
equipment for non-intrusive monitoring.
Once the G.772 Monitoring is implemented, the receiver of channel 0
During the G.772 Monitoring, channel 0 processes as normal after
The signal which is monitored goes through the Clock & Data
In monitoring mode, channel 0 can be configured to Remote Loop-
RDn/RDPn
RDNn/RMFn
RCLKn/RMFn
TCLKn/TDNn
TDNn/TMFn
TDn/TDPn
RD0/RDP0
RDN0/RMF0
RCLK0/RMF0
TCLK0/TDN0
TDN0/TMF0
TD0/TDP0
February 6, 2009

Related parts for IDT82P2816BB