M55800A Atmel Corporation, M55800A Datasheet - Page 75

no-image

M55800A

Manufacturer Part Number
M55800A
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of M55800A

Flash (kbytes)
0 Kbytes
Pin Count
176
Max. Operating Frequency
33 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
58
Ext Interrupts
58
Usb Speed
No
Usb Interface
No
Spi
1
Uart
3
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
72
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
8
Self Program Memory
NO
External Bus Interface
1
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3/5.0
Fpu
No
Mpu / Mmu
no / no
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
No
13.2
13.2.1
13.2.2
13.2.3
1745F–ATARM–06-Sep-07
Functional Description
Timing
Alarm
Error Checking
The RTC provides a full Binary-Coded Decimal (BCD) clock which includes century (19/20), year
(with leap years), month, date, day, hours, minutes and seconds.
The valid year range is 1900 to 2099, a two-hundred year Gregorian calendar achieving full Y2K
compliance.
The RTC can operate in 24-hour mode or in 12-hour mode with an AM/PM indicator.
Corrections for leap years are included (all years divisible by 4 being leap years, including year
2000). This is correct up to the year 2099.
The RTC is updated in real-time at one second intervals in normal mode for the counters of sec-
onds, at 1 minute intervals for the counter of minutes and so on.
Due to the asynchronous operation of the RTC with respect to the rest of the chip, to be certain
that the value read in the RTC registers (century, year, month, date, day, hours, minutes, sec-
onds) are valid and stable, it is necessary to read these registers twice. If the data is the same
both times, then it is valid. Therefore, a minimum of two and a maximum of three accesses is
required.
The RTC has five programmable fields with which to program an alarm: MONTH and DATE in
the Calendar Alarm Register (RTC_CAR), and SEC, MIN and HOUR in the Time Alarm Register
(RTC_TAR). Each of these fields can be enabled or disabled using the bits MTHEN, DATEN,
SECEN, MINEN, HOUREN to match the alarm condition.
A verification on user interface data is performed when accessing the century, year, month,
date, day, hours, minutes, seconds and alarms. A check is performed on illegal BCD entries
such as illegal date of the month with regards to the year and century configured.
If one of the time fields is not correct, the data is not loaded into the register/counter and a flag is
set in the Valid Entry Register (RTC_VER). This flag cannot be reset by the user. It is reset as
soon as an acceptable value is programmed. This avoids any further side effects in the hard-
ware. The same processing is done for the alarm.
The following checks are processed:
• If all the fields are enabled, an alarm flag is generated (the corresponding flag is asserted
• If only the “seconds” field is enabled, then an alarm is generated every minute.
• Depending on the combination of fields enabled, a large number of possibilities are available
1. Century (check if it is in range 19 - 20)
2. Year (BCD entry check)
3. Date (check range 01 - 31)
4. Month (check if it is in BCD range 01 - 12,
5. Day (check range 1 - 7)
and an interrupt generated if enabled) at a given month, date, hour, minute and second.
to the user ranging from minutes to 365/366 days.
check validity regarding “date”)
AT91M5880A
75