Datasheets
25.1.16.13
Name:
Address:
Access:
This register can only be written if the WPEN bit is cleared in
• CSS: Master Clock Source Selection
• PRES: Programmable Clock Prescaler
11090A–ATARM–10-Feb-12
11090A–ATARM–10-Feb-12
31
23
15
7
Value
Value
0
1
2
3
4
0
1
2
3
4
5
6
PMC Programmable Clock Register
PMC_PCKx
0x400E0440
Read-write
Name
SLOW_CLK
MAIN_CLK
PLLA_CLK
PLLB_CLK
MCK
Name
CLK_1
CLK_2
CLK_4
CLK_8
CLK_16
CLK_32
CLK_64
30
22
14
6
PRES
29
21
13
5
Description
Slow Clock is selected
Main Clock is selected
PLLA Clock is selected
PLLB Clock is selected
Master Clock is selected
Description
Selected clock
Selected clock divided by 2
Selected clock divided by 4
Selected clock divided by 8
Selected clock divided by 16
Selected clock divided by 32
Selected clock divided by 64
28
20
12
4
“PMC Write Protect Mode Register”
27
19
11
3
26
18
10
2
SAM3S8/SD8
SAM3S8/SD8
CSS
.
25
17
9
1
24
16
8
0