AD7142 Analog Devices, AD7142 Datasheet - Page 14

no-image

AD7142

Manufacturer Part Number
AD7142
Description
Programmable Controller for Capacitance Touch Sensors
Manufacturer
Analog Devices
Datasheet

Specifications of AD7142

Resolution (bits)
16bit
# Chan
14
Sample Rate
250kSPS
Interface
I²C/Ser 2-Wire,Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
± 2 pF (Delta C)
Adc Architecture
Sigma-Delta
Pkg Type
CSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7142ACPZ-1
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7142ACPZ-1500
Manufacturer:
ADI
Quantity:
10
Part Number:
AD7142ACPZ-1500
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7142ACPZ-1500RL7
Manufacturer:
ADI
Quantity:
8 000
Part Number:
AD7142ACPZ-1REEL
Manufacturer:
NXP
Quantity:
2 007
AD7142
CAPACITANCE SENSOR INPUT CONFIGURATION
Each input connection from the external capacitance sensors to
the AD7142 converter can be uniquely configured by using the
registers in Table 45 and Table 46. These registers are used to
configure input pin connection setups, sensor offsets, sensor
sensitivities, and sensor limits for each stage. Each sensor can be
individually optimized. For example, a button sensor connected
to STAGE0 can have different sensitivity and offset values than
a button with a different function that is connected to a
different stage.
CIN INPUT MULTIPLEXER SETUP
The CIN_CONNECTION_SETUP registers in Table 45 list the
different options that are provided for connecting the sensor
input pin to the CDC.
The AD7142 has an on-chip multiplexer to route the input
signals from each pin to the input of the converter. Each input
pin can be tied to either the negative or the positive input of the
CIN10
CIN12
CIN13
CIN11
CIN0
CIN1
CIN2
CIN3
CIN4
CIN5
CIN6
CIN7
CIN8
CIN9
Figure 21. Input Mux Configuration Options
CIN_CONNECTION
_SETUP BITS
00
01
10
11
Rev. A | Page 14 of 72
CINX FLOATING
CINX CONNECTED TO
NEGATIVE CDC INPUT
CINX CONNECTED TO
POSITIVE CDC INPUT
CINX CONNECTED TO
C
CIN SETTING
SHIELD
CDC, or it can be left floating. Each input can also be internally
connected to the C
an input is not used, always connect it to C
Connecting a CINx input pin to the positive CDC input results
in a decrease in CDC output code when the corresponding
sensor is activated. Connecting a CINx input pin to the negative
CDC input results in an increase in CDC output code when the
corresponding sensor is activated.
The multiplexer settings for each conversion sequence can be
unique and different for each of the input pins, CIN0 to CIN13.
For example, CIN0 is connected to the negative CDC input for
conversion STAGE1, left floating for sequencer STAGE1, and so
on for all twelve conversion stages.
Two bits in each sequence stage register control the mux setting for
the input pin.
+
SHIELD
CDC
signal to help prevent cross coupling. If
SHIELD.

Related parts for AD7142