AD7142 Analog Devices, AD7142 Datasheet - Page 40

no-image

AD7142

Manufacturer Part Number
AD7142
Description
Programmable Controller for Capacitance Touch Sensors
Manufacturer
Analog Devices
Datasheet

Specifications of AD7142

Resolution (bits)
16bit
# Chan
14
Sample Rate
250kSPS
Interface
I²C/Ser 2-Wire,Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
± 2 pF (Delta C)
Adc Architecture
Sigma-Delta
Pkg Type
CSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7142ACPZ-1
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7142ACPZ-1500
Manufacturer:
ADI
Quantity:
10
Part Number:
AD7142ACPZ-1500
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7142ACPZ-1500RL7
Manufacturer:
ADI
Quantity:
8 000
Part Number:
AD7142ACPZ-1REEL
Manufacturer:
NXP
Quantity:
2 007
AD7142
DETAILED REGISTER DESCRIPTIONS
BANK 1 REGISTERS
All addresses and default values are expressed in hexadecimal.
Table 19. PWR_CONTROL Register
Address
0x000
Data Bit
[1:0]
[3:2]
[7:4]
[9:8]
[10]
[11]
[12]
[13]
[15:14]
Default Value
0
0
0
0
0
0
0
0
0
R/W
Type
Name
POWER_MODE
LP_CONV_DELAY
SEQUENCE_STAGE_NUM
DECIMATION
SW_RESET
INT_POL
EXCITATION_SOURCE
SRC
CDC_BIAS
Rev. A | Page 40 of 72
Description
Operating modes
Low power mode conversion delay
Number of stages in sequence (N + 1)
ADC decimation factor
Software reset control (self-clearing)
Interrupt polarity control
Excitation source control for Pin 15
Excitation source control for Pin 16
CDC bias current control
0 = active low
1 = active high
00 = full power mode (normal operation, CDC
conversions approximately every 36 ms)
01 = full shutdown mode (no CDC conversions)
10 = low power mode (automatic wake up operation)
11 = full shutdown mode (no CDC conversions)
00 = 200 ms
01 = 400 ms
10 = 600 ms
11 = 800 ms
00 = decimate by 256
01 = decimate by 128
10 = do not use this setting
11 = do not use this setting
1 = resets all registers to default values
0 = enable output
1 = disable output
0 = enable output
1 = disable output
00 = normal operation
01 = normal operation + 20%
10 = normal operation + 35%
11 = normal operation + 50%
0000 = 1 conversion stage in sequence
0001 = 2 conversion stages in sequence
Maximum value = 1011 = 12 conversion stages per
sequence

Related parts for AD7142