AD7142 Analog Devices, AD7142 Datasheet - Page 37

no-image

AD7142

Manufacturer Part Number
AD7142
Description
Programmable Controller for Capacitance Touch Sensors
Manufacturer
Analog Devices
Datasheet

Specifications of AD7142

Resolution (bits)
16bit
# Chan
14
Sample Rate
250kSPS
Interface
I²C/Ser 2-Wire,Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
± 2 pF (Delta C)
Adc Architecture
Sigma-Delta
Pkg Type
CSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7142ACPZ-1
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7142ACPZ-1500
Manufacturer:
ADI
Quantity:
10
Part Number:
AD7142ACPZ-1500
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7142ACPZ-1500RL7
Manufacturer:
ADI
Quantity:
8 000
Part Number:
AD7142ACPZ-1REEL
Manufacturer:
NXP
Quantity:
2 007
POWER-UP SEQUENCE
When the AD7142 is powered up, the following sequence is
recommended when initially developing the AD7142 and μP
serial interface:
1.
2.
3.
CONVERSION
STAGE
Turn on the power supplies to the AD7142.
Write to the Bank 2 registers at Address 0x080 through
Address 0x0DF. These registers are contiguous so a
sequential register write sequence can be applied.
Note: The Bank 2 register values are unique for each
application. Register values are provided by Analog
Devices after the sensor board has been developed.
Write to the Bank 1 registers at Address 0x000 through
Address 0x007 as follows. These registers are contiguous so
a sequential register write sequence can be applied (see
Figure 47 and Figure 52).
Caution: At this time, Address 0x001 must remain set to
default value 0x0000 during this contiguous write
operation.
Register values:
Address 0x000 = 0x00B2
Address 0x001 = 0x0000
Address 0x002 = 0x3230
CONVERSION STAGES DISABLED
0
1
2
Figure 56. Recommended Start-Up Sequence
3
FIRST CONVERSION SEQUENCE
4
5
Rev. A | Page 37 of 72
6
7
8
9
4.
5.
6.
10
11
Address 0x003 = 0x14C8
Address 0x004 = 0x0832
Address 0x005 = 0x0000
Address 0x006 = 0x0000
Address 0x007 = 0x0001 (The AD7142 interrupt is asserted
approximately every 36 ms.)
Write to the Bank 1 register, Address 0x001 = 0x0FFF.
Read back the corresponding interrupt status register at
Address 0x008, Address 0x009, or Address 0x00A. This is
determined by the interrupt output configuration as
explained in the Interrupt Output section.
Note: The specific registers required to be read back
depend on each application. Analog Devices provides this
information after the sensor board has been developed.
Repeat Step 5 every time INT is asserted.
0
1
2
SECOND CONVERSION
SEQUENCE
9
10
11
0
1
2
THIRD CONVERSION
SEQUENCE
9
10
AD7142
11
0
1

Related parts for AD7142