Specifications of ADP8860
Vin Range
2.4V to 5.5V
Vout (v)
4.3 to 5.5
Synchronous
No
Package
20-Lead WLCSP
Led Configuration
Parallel
Topology
Capacitive
I2c Support
Yes
Max Iout (ma)
60mA
Brightness Control
I2C
Peak Efficiency (%)
89%
Switching Frequency
1MHz
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADP8860ACBZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADP8860ACPZ
Manufacturer:
SPECTR
Quantity:
10 400
Part Number:
ADP8860BCBZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADP8860XCBZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Mode Control Register 2 (MDCR2)—Register 0x02
Table 12. MDCR2 Bit Map
Bit 7
Table 13. Bit Descriptions for the MDCR2 Register
Bit Name
N/A
SHORT_INT
TSD_INT
OVP_INT
CMP2_INT
CMP_INT
1
Interrupt Enable (INTR_EN)—Register 0x03
Table 14. INTR_EN Bit Map
Bit 7
Table 15. Bit Descriptions for the INTR_EN Register
Bit Name
N/A
SHORT_IEN
TSD_IEN
OVP_IEN
CMP2_IEN
Interrupt bits are cleared by writing a 1 to the flag; writing a 0 or reading the flag has no effect.
Bit 6
Bit 6
Reserved
Reserved
Bit No.
7:5
4
3
2
1
Bit No.
7:5
4
3
2
1
0
Description
Reserved.
Short-circuit interrupt is enabled. When the SHORT_INT status bit is set after an error condition, an interrupt is
raised to the host if the SHORT_IEN flag is enabled.
1 = the short-circuit interrupt is enabled.
0 = the short-circuit interrupt is disabled (the SHORT_INT flag continues to assert).
Thermal shutdown interrupt is enabled. When the TSD_INT status bit is set after an error condition, an interrupt is
raised to the host if the TSD_IEN flag is enabled.
1 = the thermal shutdown interrupt is enabled.
0 = the thermal shutdown interrupt is disabled (the TSD_INT flag continues to assert).
Overvoltage interrupt enabled. When the OVP_INT status bit is set after an error condition, an interrupt is raised to
the host if the OVP_IEN flag is enabled.
1 = the overvoltage interrupt is enabled.
0 = the overvoltage interrupt is disabled (the OVP_INT flag continues to assert).
When the CMP2_INT status bit is set after an enabled comparator trips, an interrupt is raised if the CMP2_IEN flag is
enabled.
1 = the second phototransistor comparator interrupt is enabled.
0 = the second phototransistor comparator interrupt is disabled (the CMP2_INT flag continues to assert).
Bit 5
Bit 5
Description
Reserved.
Short-circuit error.
1 = a short-circuit or overload condition on VOUT was detected.
0 = no short-circuit or overload condition has been detected.
Thermal shutdown.
1 = the device temperature has exceeded 150°C (typical).
0 = no overtemperature condition has been detected.
Overvoltage interrupt.
1 = VOUT has exceeded V
0 = VOUT has not exceeded V
1 = indicates that the second ALS comparator (CMP_IN2) has changed state.
0 = the second sensor comparator has not triggered.
1 = indicates that the main ALS comparator (CMP_IN) has changed state.
0 = the main sensor comparator has not triggered.
Bit 4
SHORT_INT
Bit 4
SHORT_IEN
1
OVP
Bit 3
.
Rev. 0 | Page 29 of 52
TSD_INT
Bit 3
TSD_IEN
OVP
.
Bit 2
OVP_INT
Bit 2
OVP_IEN
Bit 1
CMP2_INT
Bit 1
CMP2_IEN
Bit 0
Bit 0
CMP_INT
CMP_IEN
ADP8860