Z8S180 Zilog., Z8S180 Datasheet - Page 33

no-image

Z8S180

Manufacturer Part Number
Z8S180
Description
ENHANCED Z180 MICROPROCESSOR
Manufacturer
Zilog.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8S18010FEC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FEC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FEG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSCZ180
Manufacturer:
ZILOG
Quantity:
748
Part Number:
Z8S18010FSG
Manufacturer:
Zilog
Quantity:
426
Part Number:
Z8S18010PSG
Manufacturer:
Zilog
Quantity:
48
Part Number:
Z8S18010VEC
Manufacturer:
ZILOG
Quantity:
12 388
Part Number:
Z8S18010VSC
Manufacturer:
ZILOG
Quantity:
250
18
UM005001-ZMP0400
Z 8018x Fam il y
M PU Us e r M anual
CPU Timing
Note:
This section explains the Z8X180 CPU timing for the following operations:
The basic CPU operation consists of one or more Machine Cycles (MC).
A machine cycle consists of three system clocks, T1, T2, and T3 while
accessing memory or I/O, or it consists of one system clock (T1) during
CPU internal operations. The system clock is half the frequency of the
Crystal oscillator (that is, an 8-MHz crystal produces 4 MHz or 250 nsec).
For interfacing to slow memory or peripherals, optional Wait States (TW)
may be inserted between T2 and T3.
Instruction (Op Code) Fetch Timing
Figure 9 illustrates the instruction (Op Code) fetch timing with no Wait
States. An Op Code fetch cycle is externally indicated when the M1
output pin is Low.
In the first half of T1, the address bus (A0 –A19) is driven from the
contents of the Program Counter (PC). This address bus is the translated
address output of the Z8X180 on-chip MMU.
In the second half of T1, the MREQ. (Memory Request) and RD (Read)
signals are asserted Low, enabling the memory.
Instruction (Op Code) fetch timing
Operand and data read/write timing
I/O read/write timing
Basic instruction (fetch and execute) timing
RESET timing
BUSREQ/BUSACK bus exchange timing
The user must program the Operation Mode Control Register
before the first I/O instruction is executed.