Serial Communications Interface Module (SCI)
MC68HC08AZ60 — Rev 1.0
200
NOTE:
NOTE:
RE — Receiver Enable Bit
Writing to the RE bit is not allowed when the enable SCI bit (ENSCI) is
clear. ENSCI is in SCI control register 1.
RWU — Receiver Wakeup Bit
SBK — Send Break Bit
Do not toggle the SBK bit immediately after setting the SCTE bit.
Toggling SBK before the preamble begins causes the SCI to send a
break character instead of a preamble.
Freescale Semiconductor, Inc.
Setting this read/write bit enables the receiver. Clearing the RE bit
disables the receiver but does not affect receiver interrupt flag bits.
Reset clears the RE bit.
This read/write bit puts the receiver in a standby state during which
receiver interrupts are disabled. The WAKE bit in SCC1 determines
whether an idle input or an address mark brings the receiver out of the
standby state and clears the RWU bit. Reset clears the RWU bit.
Setting and then clearing this read/write bit transmits a break
character followed by a logic 1. The logic 1 after the break character
guarantees recognition of a valid start bit. If SBK remains set, the
transmitter continuously transmits break characters with no logic 1s
between them. Reset clears the SBK bit.
Serial Communications Interface Module (SCI)
For More Information On This Product,
1 = Receiver enabled
0 = Receiver disabled
1 = Standby state
0 = Normal operation
1 = Transmit break characters
0 = No break characters being transmitted