SAB80C517-M16 SIEMENS [Siemens Semiconductor Group], SAB80C517-M16 Datasheet - Page 219

no-image

SAB80C517-M16

Manufacturer Part Number
SAB80C517-M16
Description
8-Bit CMOS Single-Chip Microcontroller
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet
MOV
Function:
Description:
Example:
MOV
Operation:
Encoding:
Bytes:
Cycles:
MOV
Operation:
Encoding:
Bytes:
Cycles:
Semiconductor Group
<dest-bit>, <src-bit>
C,bit
bit,C
Move bit data
The Boolean variable indicated by the second operand is copied into the location
specified by the first operand. One of the operands must be the carry flag; the other
may be any directly addressable bit. No other register or flag is affected.
The carry flag is originally set. The data present at input port 3 is 11000101 B . The
data previously written to output port 1 is 35 H (00110101 B ).
MOV
MOV
MOV
will leave the carry cleared and change port 1 to 39 H (00111001 B ).
MOV
(C)
2
1
MOV
(bit)
2
2
1 0 1 0
1 0 0 1
(bit)
(C)
P1.3,C
C,P3.3
P1.2,C
0 0 1 0
0 0 1 0
220
bit address
bit address
Instruction Set