PEB3086 Infineon Technologies, PEB3086 Datasheet - Page 86
PEB3086
Manufacturer Part Number
PEB3086
Description
ISDN Subscriber Access Controller
Manufacturer
Infineon Technologies
Datasheet
1.PEB3086.pdf
(262 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
PEB3086F
Manufacturer:
INFINEON
Quantity:
85
Company:
Part Number:
PEB3086F
Manufacturer:
HARRIS
Quantity:
104
Company:
Part Number:
PEB3086FV1.4
Manufacturer:
INFINEON
Quantity:
183
Part Number:
PEB3086FV1.4
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEB3086FV14
Manufacturer:
RENESAS
Quantity:
2 720
Company:
Part Number:
PEB3086H
Manufacturer:
INFINEON
Quantity:
9
Part Number:
PEB3086H-V1-4
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3086HV1.4
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
or an internal timer of 32 ms expires.
G4 wait for DR
Final state after a deactivation request. The transceiver remains in this state until DC is
issued.
Unconditional States
Test Mode SSP
Send Single Pulses
Test Mode SCP
Send Continuous Pulses
3.5.3.3
Command
Deactivation
Request
Reset
Send Single Pulses
Send Continuous
Pulses
Receiver not
Synchronous
Activation Request
Activation Request
Loop
Activation Indication AI
Data Sheet
C/I Codes (NT)
AR
Abbr.
DR
RES
SSP
SCP
RSY
ARL
Code
0000
0001
0010
0011
0100
1000
1010
1100
Send Continuous Pulses.
Remark
DR - Deactivation Request. Initiates a complete
deactivation from the exchange side by
transmitting INFO 0. Unconditional command.
Reset of state machine. Transmission of Info0.
No reaction to incoming infos. RES is an
unconditional command.
Send Single Pulses.
Receiver is not synchronous
Activation Request. This command is used to
start an exchange initiated activation.
Activation request loop. The transceiver is
requested to operate an analog loop-back close
to the S/T-interface.
Synchronous receiver, i.e. activation
completed.
86
Description of Functional Blocks
PEB 3086
2003-01-30
ISAC-SX