ATSAM3X4EA-AU Atmel, ATSAM3X4EA-AU Datasheet - Page 130

no-image

ATSAM3X4EA-AU

Manufacturer Part Number
ATSAM3X4EA-AU
Description
ARM Microcontrollers - MCU QFP144,GREEN, IND TEMP, MRL A
Manufacturer
Atmel
Datasheet

Specifications of ATSAM3X4EA-AU

Rohs
yes
Core
ARM Cortex M3
Processor Series
SAM3X
Data Bus Width
32 bit
Maximum Clock Frequency
84 MHz
Program Memory Size
256 KB
Data Ram Size
64 KB
On-chip Adc
Yes
Operating Supply Voltage
2.4 V to 3.6 V
Operating Temperature Range
- 40 C to +85 C
Package / Case
LQFP-144
Mounting Style
SMD/SMT
Factory Pack Quantity
60

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATSAM3X4EA-AU
Manufacturer:
Atmel
Quantity:
10 000
12.14.2
12.14.2.1
12.14.2.2
12.14.2.3
12.14.2.4
12.14.2.5
130
130
UMULL
SMLAL
SAM3X/A
SAM3X/A
UMULL, UMLAL, SMULL, and SMLAL
Syntax
Operation
Restrictions
Condition flags
Examples
R0, R4, R5, R6
R4, R5, R3, R8
Signed and Unsigned Long Multiply, with optional Accumulate, using 32-bit operands and pro-
ducing a 64-bit result.
where:
op
cond
RdHi, RdLo
Rn, Rm
The UMULL instruction interprets the values from Rn and Rm as unsigned integers. It multiplies
these integers and places the least significant 32 bits of the result in RdLo, and the most signifi-
cant 32 bits of the result in RdHi.
The UMLAL instruction interprets the values from Rn and Rm as unsigned integers. It multiplies
these integers, adds the 64-bit result to the 64-bit unsigned integer contained in RdHi and RdLo,
and writes the result back to RdHi and RdLo.
The SMULL instruction interprets the values from Rn and Rm as two’s complement signed inte-
gers. It multiplies these integers and places the least significant 32 bits of the result in RdLo, and
the most significant 32 bits of the result in RdHi.
The SMLAL instruction interprets the values from Rn and Rm as two’s complement signed inte-
gers. It multiplies these integers, adds the 64-bit result to the 64-bit signed integer contained in
RdHi and RdLo, and writes the result back to RdHi and RdLo.
In these instructions:
These instructions do not affect the condition code flags.
• do not use SP and do not use PC
• RdHi and RdLo must be different registers.
op{cond} RdLo, RdHi, Rn, Rm
UMULL Unsigned Long Multiply.
UMLAL Unsigned Long Multiply, with Accumulate.
SMULL Signed Long Multiply.
SMLAL Signed Long Multiply, with Accumulate.
is one of:
is an optional condition code, see
are the destination registers.
For UMLAL and SMLAL they also hold the accumulating value.
are registers holding the operands.
; Unsigned (R4,R0) = R5 x R6
; Signed (R5,R4) = (R5,R4) + R3 x R8
“Conditional execution” on page
11057B–ATARM–28-May-12
11057B–ATARM–28-May-12
100.