ICE2A265 Infineon Technologies, ICE2A265 Datasheet - Page 16

IC OFFLINE CTRLR SMPS CM 8DIP

ICE2A265

Manufacturer Part Number
ICE2A265
Description
IC OFFLINE CTRLR SMPS CM 8DIP
Manufacturer
Infineon Technologies
Series
CoolSET®F2r
Type
Off Line Switcherr
Datasheet

Specifications of ICE2A265

Package / Case
8-DIP (0.300", 7.62mm)
Output Isolation
Isolated
Frequency Range
93 ~ 107kHz
Voltage - Input
8.5 ~ 22 V
Voltage - Output
650V
Power (watts)
52W
Operating Temperature
-40°C ~ 150°C
Output Voltage
650 V
Input / Supply Voltage (max)
22 V
Input / Supply Voltage (min)
- 0.3 V
Duty Cycle (max)
72 %
Switching Frequency
100 KHz
Supply Current
6.1 mA
Operating Temperature Range
- 40 C to + 150 C
Mounting Style
Through Hole
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Output Power
52 W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ICE2A265IN
ICE2A265X
ICE2A265XK
ICE2A265XTIN
ICE2A265XTIN
SP000013503

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICE2A265
Manufacturer:
HOLTEK
Quantity:
3 000
Part Number:
ICE2A265
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
ICE2A265
Manufacturer:
INFINEON
Quantity:
5 913
Part Number:
ICE2A265
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
ICE2A265
Quantity:
4 800
Part Number:
ICE2A265FKLA1
Quantity:
2 000
Part Number:
ICE2A265Z
Manufacturer:
INFINEON
Quantity:
570
But the Soft-Start Phase must be finished within the
Start Up Phase to force the voltage at pin FB below the
failure detection threshold of 4.8V.
3.8.2
Figure 23
Figure 23 shows the Auto Restart Mode for open loop
and no load condition. In case of this failure mode the
converter output voltage increases and also VCC. An
additional protection by the comparators C1, C2 and
the AND-gate G1 is implemented to consider this
failure mode (see Figure 24).The overvoltage detection
is provided by Comparator C1 only in the first time
during the Soft-Start Phase till the Soft-Start voltage
exceeds the threshold of the Comparator C2 at 4.0V
and the voltage at pin FB is above 4.8V. When VCC
exceeds 16.5V during the overvoltage detection phase
C1 can set the Error-Latch and the Burst Phase during
Auto Restart Mode is finished earlier. In that case
T
Version 2.6
Burst2
16.5V
13.5V
Driver
SoftS
8.5V
5.3V
4.0V
VCC
4.8V
FB
is shorter than T
5µs Blanking
Open loop & no load condition
Overvoltage due to Open Loop with
No Load
Auto Restart Mode
Detection
Failure
Detection Phase
Overvoltage
Soft-Start
Soft-Start Phase
Overvoltage Detection
T
Burst2
. By means of C2 the
T
Restart
t
t
t
t
16
normal operation mode is prevented from overvoltage
detection due to varying of VCC concerning the
regulation of the converter output. When the voltage
V
deactivated.
Figure 24
3.8.3
Thermal Shut Down is latched by the Error-Latch when
junction temperature T
exceeding an internal threshold of 140°C. In that case
the IC switches in Auto Restart Mode.
Note:
SoftS
SoftS
C
Soft-Start
is above 4.0V the overvoltage detection by C1 is
All the values which are mentioned in the
functional description are typical. Please refer
to Electrical Characteristics for min/max limit
values.
6.5V
Thermal Shut Down
Overvoltage Detection
T1
R
VCC
Soft-Start
16.5V
4.0V
Functional Description
j
Power Up Reset
C1
C2
of the pwm controller is
CoolSET™-F2
G1
25 Dec 2006
Error Latch

Related parts for ICE2A265