TLE7209-2R Infineon Technologies, TLE7209-2R Datasheet - Page 11

no-image

TLE7209-2R

Manufacturer Part Number
TLE7209-2R
Description
IC H-BRIDGE 7A DC MOTOR PDSO-20
Manufacturer
Infineon Technologies
Type
Half Bridge DC Motor Driverr
Datasheet

Specifications of TLE7209-2R

Applications
DC Motor Controller, Stepper Motor Controller
Number Of Outputs
1
Current - Output
5A
Voltage - Supply
5 V ~ 28 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
DSO-20
Operating Supply Voltage
5 V to 28 V
Supply Current
30 mA
Mounting Style
SMD/SMT
Packages
PG-DSO-20
Current Limit (min.)
5.5 A
Rthjc (max)
1.5 K/W
Quiescent Current (max.)
20mA
Operating Range
5 - 28 V
Rds (on) (typ./switch)
150.0 mOhm
For Use With
DEMOBOARDTLE7209-2RIN - BOARD DEMO FOR TLE 7209-2R
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SP000014748
SP000294312
TLE72092RNT
TLE72092RT
TLE72092RXT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE7209-2R
Manufacturer:
INFINEON
Quantity:
18
Part Number:
TLE7209-2R
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE7209-2R
0
Company:
Part Number:
TLE7209-2R
Quantity:
4 800
Part Number:
TLE7209-2R/R
Manufacturer:
INTERSIL
Quantity:
20 000
6. Because only read access is used in the TLE 7209-2R, the SDI data-bits (2nd byte)
7. Invalid instruction/access:
8. Transfer error bit TRANS_F:
Final Datasheet
are not used
An instruction is invalid if an unused instruction code is detected (see tables with SPI
instructions). In case an unused instruction code occurred, the data byte “ff
error) will be transmitted after having sent the verification byte. This transmission
takes place within the same SPI-frame that contained the unused instruction byte. In
addition any transmission is invalid if the number of SPI clock pulses (falling edge)
counted during active CSN differs from exactly 16 clock pulses. If an invalid instruction
is detected, bit TRANS_F in the following verification byte (next SPI transmission) is
set to HIGH. The TRANS_F bit must not be cleared before it has been sent to the
microcontroller.
The bit TRANS_F indicates an error during the previous transfer. An error is
considered to have occurred when an invalid command was sent, the number of SPI
clock pulses (falling edge) counted during active CSN was less than or greater than
16 clock pulses, or SPI clock (SCK) was logical high during falling edge of CSN.
11
Circuit Description
V1.3, 2005-jan-11
TLE 7209-2R
hex
” (no

Related parts for TLE7209-2R