TLE7209-2R Infineon Technologies, TLE7209-2R Datasheet - Page 16

no-image

TLE7209-2R

Manufacturer Part Number
TLE7209-2R
Description
IC H-BRIDGE 7A DC MOTOR PDSO-20
Manufacturer
Infineon Technologies
Type
Half Bridge DC Motor Driverr
Datasheet

Specifications of TLE7209-2R

Applications
DC Motor Controller, Stepper Motor Controller
Number Of Outputs
1
Current - Output
5A
Voltage - Supply
5 V ~ 28 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
DSO-20
Operating Supply Voltage
5 V to 28 V
Supply Current
30 mA
Mounting Style
SMD/SMT
Packages
PG-DSO-20
Current Limit (min.)
5.5 A
Rthjc (max)
1.5 K/W
Quiescent Current (max.)
20mA
Operating Range
5 - 28 V
Rds (on) (typ./switch)
150.0 mOhm
For Use With
DEMOBOARDTLE7209-2RIN - BOARD DEMO FOR TLE 7209-2R
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SP000014748
SP000294312
TLE72092RNT
TLE72092RT
TLE72092RXT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE7209-2R
Manufacturer:
INFINEON
Quantity:
18
Part Number:
TLE7209-2R
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE7209-2R
0
Company:
Part Number:
TLE7209-2R
Quantity:
4 800
Part Number:
TLE7209-2R/R
Manufacturer:
INTERSIL
Quantity:
20 000
Table 10
Failure Encoding in case of multiple faults
If multiple faults are stored in the failure register, the faults that are encoded in the DIAxx
bits can not be displayed simultaneously due to the encoding scheme that is used. In this
case, errors are encoded according to the following priority list.
– Priority 1: Under Voltage (please note that after removal of Under Voltage, the original
– Priority 2: Short circuit across the load
– Priority 3: all other short circuits
– Priority 4: open load
If a failure of higher priority is detected, the failures of lower priority are no longer visible
in the encoded SPI message.
Fault storage and reset of the Diagnosis Register DIA_REG
Register DIA_REG is reset upon the following conditions:
– With the rising edge of the CSN-Signal after the SPI-instruction RD_DIA. This reset
– When the voltage on DMS exceeds the threshold for detecting SPI-Mode (after Under
– A rising edge on EN while DIS=0 or a falling edge on DIS while EN=1 re-activates the
Final Datasheet
DIA21 DIA20 DIA11 DIA10 Description
1
-
-
-
0
0
1
1
0
error will be restored, see below)
only takes place if the correct number of 16 SCK pulses has been counted.
Voltage condition). Under Voltage on Vs (typ. < 5,0V) sets Bit 0.... Bit 3 of DIA_REG
to 0000. If Vs rises above the Under Voltage level, Bits of DIA_REG are restored
(when DMS > 3.5V).
output power-stages, and resets the DIA_REG register.
1
-
-
-
0
1
0
1
0
Encoding of the Diagnostic Bits of OUT1 and OUT2
0
0
1
1
1
-
-
-
0
0
1
0
1
1
-
-
-
0
Short circuit over load (SCOL)
Short circuit to battery on OUT1 (SCB1) latched
Short circuit to ground on OUT1 (SCG1) latched
No error detected on OUT1
Open load (OL)
Short circuit to battery on OUT2 (SCB2) latched
Short circuit to ground on OUT2 (SCG2) latched
No error detected on OUT2
Under Voltage on Pin Vs
16
Circuit Description
V1.3, 2005-jan-11
TLE 7209-2R
latch
behavior
latched
-
latched
-
not latched

Related parts for TLE7209-2R