XCCACE128-I Xilinx Inc, XCCACE128-I Datasheet - Page 66

no-image

XCCACE128-I

Manufacturer Part Number
XCCACE128-I
Description
IC 128MBIT ACE FLASH CARD
Manufacturer
Xilinx Inc
Datasheet

Specifications of XCCACE128-I

Memory Size
128Mb
Memory Type
FLASH
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XCCACE128-I
Manufacturer:
XILINX
0
System ACE CompactFlash Solution
Table 38: System ACE CF Controller Pin Table (IN = input, OUT2 = 2-State Output, OUT3 = 3-State Output)
66
Notes:
1.
2.
POR_RESET
POR_BYPASS
POR_TEST
Pin Name
JTAG 1149.1 requires a pull-up resistor on potentially undriven TDO/TMS signals.
If not using the RESET signal prior to CFGJTAG configuration, ensure that the V
when power-cycling the board. Failure to do this, could cause the Power-On-Reset (POR) circuitry to operate incorrectly.
(2)
Pin #
108
72
74
I/O Type
OUT2
IN
IN
I/O Supply Rail
V
V
V
CCH
CCH
CCH
www.xilinx.com
Int. Pull-down
Int. Pull-down
Termination
N/A
Power-on-reset (POR) bypass input; used in
conjunction with POR_RESET to bypass the
internal POR circuit in favor of using an external
board-level POR circuit; the internal POR circuit is
bypassed when POR_BYPASS = 1; the
POR_BYPASS pin should be held at a static 0 or 1
while the System ACE CF controller is receiving
power.
Power-on-reset bypass input; can be used in
conjunction with POR_BYPASS to bypass the
internal POR circuit in favor of using an external
board-level POR circuit; all internal circuitry is reset
when POR_BYPASS = 1 and POR_RESET = 1;
The POR_RESET pulse duration should be at least
1 microsecond long.
Power-on-reset test output; this pin should be a true
No Connect on the board (see
but is listed here for informational purposes.
POR_TEST is Low during power up and when
POR_BYPASS and POR_RESET are asserted
High (causing a device reset). After power up is
complete, POR_TEST is High when POR_BYPASS
is Low, or when POR_BYPASS is High and
POR_RESET is Low. An internal timer circuit in the
POR component determines when to release
POR_TEST after power reaches the ON threshold.
CCH
and V
CCL
are brought all the way back to 0V
Description
DS080 (v2.0) October 1, 2008
Product Specification
Table 40, page
68)
R

Related parts for XCCACE128-I