Specifications of C8051F544-IM

Program Memory Type
FLASH
Program Memory Size
8KB (8K x 8)
Package / Case
32-QFN
Mfg Application Notes
LIN Bootloader AppNote
Core Processor
8051
Core Size
8-Bit
Speed
50MHz
Connectivity
SMBus (2-Wire/I²C), LIN, SPI, UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
25
Ram Size
1.25K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.25 V
Data Converters
A/D 25x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Processor Series
C8051F5x
Core
8051
Data Bus Width
8 bit
Data Ram Size
256 B
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
25
Operating Supply Voltage
1.8 V to 5.25 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F540DK
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1672 - BOARD PROTOTYPE W/C8051F540336-1669 - KIT DEVELOPMENT FOR C8051F540
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1677-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F544-IM
Manufacturer:
Silicon Labs
Quantity:
135
SFR Definition 17.5. CLKMUL: Clock Multiplier
SFR Address = 0x97; SFR Page = 0x0F;
Notes: The maximum system clock is 50 MHz, and so the Clock Multiplier output should be scaled accordingly. 
Name
Reset
Bit
4:2
1:0
Type
7
6
5
Bit
MULSEL[1:0] Clock Multiplier Input Select.
If Internal Oscillator x 2 or External Oscillator x 2 is selected using the MULSEL bits, MULDIV[2:0] is ignored.
MULDIV[2:0]
MULRDY
MULINIT
MULEN
MULEN
Name
R/W
7
0
MULINIT
Clock Multiplier Enable.
0: Clock Multiplier disabled.
1: Clock Multiplier enabled.
Clock Multiplier Initialize.
This bit is 0 when the Clock Multiplier is enabled. Once enabled, writing a 1 to this
bit will initialize the Clock Multiplier. The MULRDY bit reads 1 when the Clock Mul-
tiplier is stabilized.
Clock Multiplier Ready.
0: Clock Multiplier is not ready.
1: Clock Multiplier is ready (PLL is locked).
Clock Multiplier Output Scaling Factor.
000: Clock Multiplier Output scaled by a factor of 1.
001: Clock Multiplier Output scaled by a factor of 1.
010: Clock Multiplier Output scaled by a factor of 1.
011: Clock Multiplier Output scaled by a factor of 2/3*.
100: Clock Multiplier Output scaled by a factor of 2/4 (1/2).
101: Clock Multiplier Output scaled by a factor of 2/5*.
110: Clock Multiplier Output scaled by a factor of 2/6 (1/3).
111: Clock Multiplier Output scaled by a factor of 2/7*.
*Note: The Clock Multiplier output duty cycle is not 50% for these settings.
These bits select the clock supplied to the Clock Multiplier
MULSEL[1:0]
R/W
6
0
00
01
10
11
MULRDY
R
5
0
Selected Input Clock
External Oscillator
External Oscillator
Internal Oscillator
Internal Oscillator
Rev. 1.1
4
0
MULDIV[2:0]
Function
R/W
3
0
2
0
Clock Multiplier Output
for MULDIV[2:0] = 000b
External Oscillator x 2
External Oscillator x 4
Internal Oscillator x 2
Internal Oscillator x 4
C8051F54x
1
MULSEL[1:0]
0
R/W
0
0