BLM18AG151SH1D Murata, BLM18AG151SH1D Datasheet - Page 23

EMI/RFI Suppressors & Ferrites 0603 150ohms Gen Use Tape

BLM18AG151SH1D

Manufacturer Part Number
BLM18AG151SH1D
Description
EMI/RFI Suppressors & Ferrites 0603 150ohms Gen Use Tape
Manufacturer
Murata
Series
BLM Ar
Datasheets

Specifications of BLM18AG151SH1D

Shielding
Unshielded
Test Frequency
100 MHz
Product
Chip Ferrite Beads
Impedance
150 Ohms
Tolerance
25 %
Maximum Dc Current
200 mAmps
Maximum Dc Resistance
0.25 Ohms
Operating Temperature Range
- 55 C to + 125 C
Package / Case
0603 (1608 metric)
Termination Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BLM18AG151SH1D
Manufacturer:
MURATA
Quantity:
240 000
2
!Note
!Note
3. Environment Performance (It should be soldered on the substrate.)
2
22
No.
Specifications and Test Methods
1
2
3
4
• Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specifications before ordering.
Humidity
Heat Life
Cold Resistance
Temperature Cycling
Item
Meet Table 4.
Table 4
Meet Table 2.
Withstanding
Cap. Change
Appearance
Voltage
I.R.
33, 68, 100, 180,
1000, 4700 (pF)
360, 680 (pF)
Specifications
100M min.
No damage
No damage
within 15%
within 30%
Temperature: 85 2 C
Humidity: 85%(RH)
Time: 1000 hrs. (+48 hrs., -0 hr.)
Then measured after exposure to room conditions for 4 to
48 hrs.
Temperature: 125 2 C
Test Voltage:
Time: 1000 hrs. (+48 hrs., -0 hr.)
Then measured after exposure to room conditions for 4 to
48 hrs.
Temperature: -55 2 C
Time: 500 hrs. (+24hrs., -0 hr.)
Then measured after exposure to room conditions for 4 to
48 hrs.
1 Cycle
Total of 500 cycles
Then measured after exposure to room conditions for 4 to
48 hrs.
33, 68, 100, 180, 360, 680 (pF): Rated Voltage x 200%
1000, 3300 (pF): Rated Voltage x 150%
1 step: -55 C (+0 C, -3 C) / 30 3 minutes.
2 step: Room Temperature / within 5 minutes.
3 step: +125 C (+3 C, -0 C) / 30 3 minutes.
4 step: Room Temperature / within 5 minutes.
Test Methods
C50E.pdf 05.1.28

Related parts for BLM18AG151SH1D