S25FL128P0XNFI001 Spansion Inc., S25FL128P0XNFI001 Datasheet - Page 12

no-image

S25FL128P0XNFI001

Manufacturer Part Number
S25FL128P0XNFI001
Description
IC, FLASH, 128MBIT, 104MHZ, WSON-8
Manufacturer
Spansion Inc.
Datasheet

Specifications of S25FL128P0XNFI001

Memory Type
Flash
Memory Size
128Mbit
Ic Interface Type
Serial, SPI
Clock Frequency
104MHz
Supply Voltage Range
2.7 To 3.6 V
Memory Case Style
WSON
No. Of Pins
8
Cell Type
NOR
Density
128Mb
Access Time (max)
20ns
Interface Type
Parallel/Serial-SPI
Boot Type
Not Required
Address Bus
1b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
WSON
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Async/Sync
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
1b
Number Of Words
128M
Supply Current
22mA
Mounting
Surface Mount
Pin Count
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S25FL128P0XNFI001
Manufacturer:
SPANSION
Quantity:
300
Part Number:
S25FL128P0XNFI001
Manufacturer:
VISION
Quantity:
2 300
7. Device Operations
7.1
7.2
7.3
7.4
7.5
7.6
12
Byte or Page Programming
Sector Erase / Bulk Erase
Monitoring Write Operations Using the Status Register
Active Power and Standby Power Modes
Status Register
Data Protection Modes
All Spansion SPI devices (S25FL-P) accept and output data in bytes (8 bits at a time).
Programming data requires two commands: Write Enable (WREN), which is one byte, and a Page Program
(PP) sequence, which consists of four bytes plus data. The Page Program sequence accepts from 1 byte up
to 256 consecutive bytes of data (which is the size of one page) to be programmed in one operation.
Programming means that bits can either be left at the current state (1 or 0), or programmed from 1 to 0.
Changing bits from 0 to 1 requires an erase operation. Before this can be applied, the bytes of the memory
need to be first erased to all 1’s (FFh) before any programming.
The Sector Erase (SE) and Bulk Erase (BE) commands set all the bits in a sector or the entire memory array
to 1. While bits can be individually programmed from a 1 to 0, erasing bits from 0 to 1 must be done on a
sector-wide (SE) or array-wide (BE) level. The memory array needs to be first erased to all 1's (FFh) before
any programming.
The host system can determine when a Write Status Register, program, or erase operation is complete by
monitoring the Write in Progress (WIP) bit in the Status Register. The Read from Status Register command
provides the state of the WIP bit.
The device is enabled and in the Active Power mode when Chip Select (CS#) is Low. When CS# is high, the
device is disabled, but may still be in the Active Power mode until all program, erase, and Write Status
Register operations have completed. The device then goes into the Standby Power mode, and power
consumption drops to I
inadvertent signals. After writing the DP command, the device ignores any further program or erase
commands, and reduces its power consumption to I
The Status Register contains the status and control bits that can be read or set by specific commands (see
Table
Spansion SPI Flash memory devices provide the following data protection methods:
Write In Progress (WIP): Indicates whether the device is performing a Write Status Register, program or
erase operation.
Write Enable Latch (WEL): Indicates the status of the internal Write Enable Latch.
Block Protect (BP2, BP1, BP0 for uniform 256 KB sector product: BP3, BP2, BP1, BP0 for uniform
64 KB sector product): Non-volatile bits that define memory area to be software-protected against
program and erase commands.
Status Register Write Disable (SRWD): Places the device in the Hardware Protected mode when this bit
is set to 1 and the WP#/ACC input is driven low. In this mode, the non-volatile bits of the Status Register
(SRWD, BP3, BP2, BP1, BP0) become read-only bits.
The Write Enable (WREN) command: Must be written prior to any command that modifies data. The
WREN command sets the Write Enable Latch (WEL) bit. The WEL bit resets (disables writes) on power-up
or after the device completes the following commands:
– Page Program (PP)
Table 11.6, Command Definitions on page
SB
. The Deep Power Down (DP) command provides additional data protection against
S25FL128P
D a t a
38):
DP
.
S h e e t
S25FL128P_00_08 September 8, 2009