S25FL128P0XNFI001 Spansion Inc., S25FL128P0XNFI001 Datasheet - Page 21

no-image

S25FL128P0XNFI001

Manufacturer Part Number
S25FL128P0XNFI001
Description
IC, FLASH, 128MBIT, 104MHZ, WSON-8
Manufacturer
Spansion Inc.
Datasheet

Specifications of S25FL128P0XNFI001

Memory Type
Flash
Memory Size
128Mbit
Ic Interface Type
Serial, SPI
Clock Frequency
104MHz
Supply Voltage Range
2.7 To 3.6 V
Memory Case Style
WSON
No. Of Pins
8
Cell Type
NOR
Density
128Mb
Access Time (max)
20ns
Interface Type
Parallel/Serial-SPI
Boot Type
Not Required
Address Bus
1b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
WSON
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Async/Sync
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
1b
Number Of Words
128M
Supply Current
22mA
Mounting
Surface Mount
Pin Count
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S25FL128P0XNFI001
Manufacturer:
SPANSION
Quantity:
300
Part Number:
S25FL128P0XNFI001
Manufacturer:
VISION
Quantity:
2 300
11.2
September 8, 2009 S25FL128P_00_08
Read Data Bytes at Higher Speed (FAST_READ: 0Bh)
The FAST_READ command reads data from the memory array at the frequency (f
input, with a maximum speed of 104 MHz. The host system must first select the device by driving CS# low.
The FAST_READ command is then written to SI, followed by a 3-byte address (A23-A0) and a dummy byte.
Each bit is latched on the rising edge of SCK. The memory array data, at that address, are output serially on
SO at a frequency f
The FAST_READ command sequence is shown in
be at any location. The device automatically increments to the next higher address after each byte of data is
output. The entire memory array can therefore be read with a single FAST_READ command. When the
highest address is reached, the address counter reverts to 00000h, allowing the read sequence to continue
indefinitely.
The FAST_READ command is terminated by driving CS# high at any time during data output. The device
rejects any FAST_READ command issued while it is executing a program, erase, or Write Status Register
operation, and continues the operation uninterrupted. Note that the FAST_READ command is not valid in
parallel mode.
SCK
SO
CS#
SI
Mode 3
Mode 0
Hi-Z
Figure 11.3 Read Data Bytes at Higher Speed (FAST_READ) Command Sequence
0
1
SCK
2
Command
, on the falling edge of SCK.
3
D a t a
4
5
6
7
S h e e t
23 22 21
8
9
24-Bit Address
S25FL128P
10
28 29 30
3
2
1
Figure 11.3
31 32 33
0
7
6
Dummy Byte
34 35 36 37 38
5
and
4
3
Table
2
1
39
0
MSB
11.6. The first byte specified can
7
40 41
6
5
42 43 44 45
DATA OUT 1
SCK
4
) presented at the SCK
3
2
1
46
0
47
MSB
7
DATA OUT 2
21

Related parts for S25FL128P0XNFI001