60118 SQUARE D, 60118 Datasheet - Page 13

MINIATURE CIRCUIT BREAKER 120V 1A

60118

Manufacturer Part Number
60118
Description
MINIATURE CIRCUIT BREAKER 120V 1A
Manufacturer
SQUARE D
Series
Multi 9r
Datasheet

Specifications of 60118

Actuator Style
Toggle
No. Of Poles
1
Current Rating
1A
Voltage Rating Vac
240V
Mounting Type
DIN Rail
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
60118-1
Manufacturer:
TE/AMP
Quantity:
30 000
Part Number:
60118-1
Manufacturer:
TE
Quantity:
90 000
Part Number:
60118-1
Manufacturer:
TE
Quantity:
35 000
Part Number:
601181B
Manufacturer:
CDI
Quantity:
339
© 2002–2010 Schneider Electric
All Rights Reserved
Table 1:
Characteristic
Labeling
Nomenclature
Dielectric test (for 240
Vac)
Interrupting rating
Overload protection
Service capacity
Calibration test
Calibration temperature
Testing temperature
Endurance
Air spacing
Surface spacing
Test and follow up tests
Comparison Summary of Applicable UL
UL
UL Listed
Circuit breakers
2 times rated plus 1000 V for 1 minute
(1,480 at 240 Vac)
10 kA at 240 Vac
50 operations at 600% rating
Must be operational after two interruptions
200% I
25°C (77°F), unless other value specified by
manufacturer
25°C (77°F) ambient, 50°C (122°F) rise max.
at terminals
6000 operations at rated current and
voltage, 75-80% PF, plus 4000 operations at
no load
3/4 in. (20.1 mm)
1-1/4 in. (31.8 mm)
Initial, periodic and quarterly follow-up tests
observed by UL representative
®
489/CSA C22.2 No. 5
UL 508 Standard—Manual Motor Controllers
UL Standard 508 covers industrial control equipment, specifically for motor control functions. It covers
individual devices as well as assemblies.
There are UL 508 Listed manual motor controllers that look much like miniature circuit breakers, and
have thermal settings and instantaneous settings similar to circuit breakers. These are specialized
devices and cannot be used for a wide range of applications, as can UL 1077 and UL 489/CSA C22.2
No.5 devices.
Like UL 1077 supplementary protectors, a UL 508 Listed manual motor controller (or a group of them)
must be protected by a UL 489/CSA C22.2 No.5 Listed branch circuit breaker.
Manual motor controllers are available from Schneider Electric (Telemecanique products GV2 and
GV3) but are not included in this catalog.
n
, 2 minutes max. (0–30 A)
®
UL
UL Recognized component
Supplementary protectors
2 times rated plus 1,000 V for 1 minute
(1,480 at 240 Vac)
10 kA at 240 Vac
50 operations at 150% rating
May be tested in series with branch circuit
device and may become inoperable after
test
Per manufacturer’s trip curve
Manufacturer must specify
25°C (77°F) ambient, 50°C (122°F) rise max.
at field wiring terminals; 65°C (149°F) rise
max. on factory wiring terminals
6000 operations at rated current and
voltage, 75-80% PF
3/8 in. (9.53 mm)
1/2 in. (12.7 mm)
Initial tests observed by UL representative,
plus quarterly visual follow-up inspection by
UL
and IEC
®
1077/CSA C22.2 No. 235
®
Standards
Multi 9™ System Catalog
IEC
IEC Certified device
Circuit breakers or supplementary protectors
1,500 V
20 kA at 240 Vac
12 operations at 600% rating
Must be operational after two interruptions
At 200% I
manufacturer’s stated value
Manufacturer must specify
At 25°C (77°F) ambient, 80°C (176°F) rise
max. at terminals
1500 operations at rated current and
voltage, 75-80% PF
See dielectric
See dielectric
Conducted by manufacturer
®
Section 1—Introduction
60947-2
n
, time shall not exceed
07/2010
13

Related parts for 60118