60118 SQUARE D, 60118 Datasheet - Page 16

MINIATURE CIRCUIT BREAKER 120V 1A

60118

Manufacturer Part Number
60118
Description
MINIATURE CIRCUIT BREAKER 120V 1A
Manufacturer
SQUARE D
Series
Multi 9r
Datasheet

Specifications of 60118

Actuator Style
Toggle
No. Of Poles
1
Current Rating
1A
Voltage Rating Vac
240V
Mounting Type
DIN Rail
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
60118-1
Manufacturer:
TE/AMP
Quantity:
30 000
Part Number:
60118-1
Manufacturer:
TE
Quantity:
90 000
Part Number:
60118-1
Manufacturer:
TE
Quantity:
35 000
Part Number:
601181B
Manufacturer:
CDI
Quantity:
339
16
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
07/2010
UL 489/CSA C22.2 No.5 Listed 240 Vac C60 Circuit Breakers (AC)
A selected range of Multi-9 circuit breakers rated 240 V are UL 489/CSA C22.2 No.5 Listed. Unlike UL
1077 Supplementary Protectors, these UL 489/CSA C22.2 No.5 circuit breakers can be used for
branch circuit protection as required by the National Electrical Code.
As shown in tables Table 5 and Table 6, the UL 489/CSA C22.2 No.5 Listed products are available in
C and D curves. They include devices ranging from 0.5 to 35 A.
UL 489/CSA C22.2 No.5 Listed Multi 9 C60 Circuit Breakers
Table 4:
Standard Features
High Voltage Withstand
Connector: Box Lug
Connector: Ring Tongue
Mounting
Degree of Protection
Temperatures
Plug-On Auxiliary Modules with
Mechanical Linkage:
Tropicalization
Number of Operating Cycles
See specifications Table 2 for dimensions, weights and interrupting ratings
Fast closing: Allows increased withstand to the high inrush currents of some loads.
Trip-free mechanism: Contacts cannot be held in the I-ON position when the C60 circuit breaker is
tripped automatically.
Positive indication of contact disconnect. Green mechanical indication on front face of circuit
breaker shows that all poles are open.
C curve: Overcurrent protection for all application types. Magnetic release operates from 7 to 10
times ampere rating (7 to 14 for DC applications).
Specifications for UL 489/CSA C22.2 No.5 240 V Listed C60 Circuit Breakers
1P
Rating
Connection
Use Single UL Listed or CSA Certified
Insulated Ring Tongue Only
Max Ring Terminal Width
35 mm DIN rail
Case
Terminals
Calibration
Storage
Operating
MN Undervoltage Trip
MX + OF Shunt Trip/Auxiliary Switch
OF Auxiliary Switch
SD Alarm Switch
Treatment 2
Electrical (O-C)
6 kV
2P
UL 486A File No. E216919 (Use with Copper Wire Only)
0.5–25 A: 14–4 AWG (2–25 mm
Torque to 22 lb-in. (2.48 N•m)
30–35 A: 14–2 AWG (1–35 mm
Torque to 31 lb-in. (3.52 N•m)
Screw dia. 0.2 in. (5 mm)
Torque to 18 lb-in. (2.03 N•m)
0.54 in. (14 mm)
IP40 as per IEC 529
IP20
25°C (77°F)
-40 to 80°C (-40 to 176°F)
-30 to 70°C (-22 to 158°F)
Relative Humidity: 95% at 131°F (55°C)
6,000 load, 4,000 no-load
© 2002–2010 Schneider Electric
2
2
) Cables
) Cables
All Rights Reserved
3P

Related parts for 60118