Power Supply Wiring
Using Round Cable I and Round Cable II or Flat Cable I/II Together
3-5-5
Allowable Current
Restrictions
96
Master Unit
Precautions when Supplying Communications Power
Open Type
Connector
Open Type
Connector
Trunk line
BS+
BS-
BS+
BDH
BDL
BS-
Terminat-
ing Resis-
tor
Note
Round cable I
Round cable I
(upstream)
PORT1
Repeater Unit
BS+ 1
BDH 1
BDL 1
BS- 1
(upstream)
PORT1
BS+ 1
BS- 1
Repeater Unit
BDH 1
BDL 1
Round cable I
I/O power supply
Power
supply
(downstream)
One or more Repeater Units can be used in a CompoNet Network to use both
round cable I and round cable II, or round cable I and Flat Cable I/II under the
same Master Unit.
The I/O power supply to multi-power supply Slave Units may be a source of
noise depending on the connected devices. Even when supplying the commu-
nications power supply together to all Slave Units, use a separate I/O power
supply so that noise does not affect the network.
When supplying communications power and I/O power, the allowable currents
of cables and connections, the voltage drop, and the capacity and location of
power supplies must be considered.
Do not allow the total current consumption of all Slave Units to exceed the
allowable current of the communications cables and connectors. Exceeding
the allowable current may result in heating or burnout of the cables or connec-
tors.
(downstream)
PORT2
BS+ 2
BS- 2
BS+ 2
BDH 2
BDL 2
BS- 2
PORT2
BS- 2
BS+ 2
BS+ 2
BDH 2
BDL 2
BS- 2
G
V
Branch line
Branch line
Downstream port communications power supply connector
Overcurrent
protection
(See note.)
(current limit: 4 A)
Overcurrent
protection
(See note.)
(current limit: 4 A)
Slave Unit
Slave Unit
Sub-
trunk
line
Sub-
trunk
line
Communications power
supply and
I/O power supply (shared)
Multidrop
Connector
Communications power
supply and
I/O power supply (shared)
G
V
Slave Unit
Power
supply
Slave Unit
V
G
Power
supply
Multi-power
supply Slave
Unit
Round cable II or Flat Cable I/II
Round cable II or Flat Cable I/II
Slave Unit
Slave Unit
Network
power supply
Slave Units
Note:
When using the UL standards, please install a
unit to restrict current between the external
power supply and this unit to 4 A. (Only
communications power supply)
Network
power supply
Slave Units
Termi-
nating
Resis-
tor
Termi-
nating
Resis-
tor
Section 3-5