CRT1-ID08TA Omron, CRT1-ID08TA Datasheet - Page 394

no-image

CRT1-ID08TA

Manufacturer Part Number
CRT1-ID08TA
Description
8 In NPN 3 Tier
Manufacturer
Omron
Datasheet

Specifications of CRT1-ID08TA

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Overview of Temperature Input Units
Input Data
Output Data
Selecting
Temperature Data
Using the CX-Integrator
370
1,2,3...
Note Data can be allocated using other data combinations if an OMRON CS/CJ-
series Master Unit is used. The settings are made in the Master Unit.
The data can be selected from six calculated values to allocate as Tempera-
ture Data 1. Select one of the following: temperature input value, peak value,
bottom value, top value, valley value, or rate of change. The selected data is
allocated in the Master Unit alone or in combination with Status Flags.
1. Turn ON the power supply to the Temperature Input Unit.
2. Double-click the icon of the Temperature Input Unit to be set in the Network
3. Click the table for the input where the temperature data is to be selected
Temperature Data 1
Normal Display: 4 input words
(8 bytes)
1/100 Display: 8 input words
(16 bytes)
Top/Valley Detection Timing
Flags (1 input word (2 bytes))
Temperature Data Status
Flag (2 input words (4 bytes))
Temperature Data 1 + Top/
Valley Detection Timing Flags
Normal Display: 5 input words
(10 bytes)
1/100 Display: 9 input words
(18 bytes)
Hold Flags
1 output word (2 bytes)
Configuration Window or right-click the icon and select Parameter - Edit.
The Configuration Window will be displayed.
and select the data to allocated in the Allocate Temperature Data 1 Field.
Output data
Input data
• Allocated to monitor temperature data.
• Select one of the following values: temperature
Note The comparator function can be used with the
Top/Valley Detection Timing Flags are allocated to
one input word. These flags are allocated together
with the top/valley value and used to time the reading
of value held as the top or valley value.
These words contain the bits for the Comparator
Result Flag, Top/Valley Detection Timing Flag, and
Disconnected Line Detection Flag. The function of
each bit is as follows:
• Comparator Result Flags:
• Top/Valley Detection Timing Flags:
• Off-wire Detection Flags:
These words contain Temperature Data 1 followed by
the Top/Valley Detection Timing Flags.
These flags are used with the hold functions (peak,
bottom, top, and valley) to control the execution tim-
ing of hold functions from the Master Unit.
Allow control of the judgement results even if tem-
perature input value is not allocated.
These flags are allocated together with the top/val-
ley value and used to time the reading of value held
as the top or valley value.
Disconnections can be detected even when the tem-
perature input value is not allocated.
input value, peak value, bottom value, top value,
valley value, or rate of change. (The temperature
input value is allocated by default.)
value allocated as Temperature Data 1.
Description
Description
Section 7-2

Related parts for CRT1-ID08TA